Laser Positioning Aid
A low-power laser located in the scanner arm indicates the exact position of the x-ray beam. The laser beam is
aligned with the narrow x-ray beam in the table and serves as an aid in marking or defining anatomical land-
marks. The laser is turned ON and OFF by pressing the LASER button
on the Scanner Arm Touch Pad.
When the laser is ON, the indicator next to the laser button is illuminated.
Although it is a low-power laser, the following precautions should be noted:
Do not stare into the beam.
Do not allow the laser to shine into your eyes. If the laser light does briefly shine into your eyes, it may startle
you, but will not cause immediate damage.
Do not allow shiny objects to reflect laser light into your eyes.
Computer/Controller
The Norland Bone Densitometer is controlled by a desktop PC. The computer is designed and configured to
operate the Norland Bone Densitometer system and should not be used for any other purpose. The computer
is certified as an X-Ray Controller at Norland's manufacturing facility, as required by the FDA.
Software
The Norland Bone Densitometer software conforms to a Windows style design for ease of use and familiarity.
Features of the Norland software include menu driven operation for system calibrations, scan data collection,
scan analysis and patient file management.
Accessories
The Norland system comes complete with the accessories listed in the next four sections.
QA Calibration Standard
The 77-step QA Calibration Standard (EmpiriCAL
™
) is an exclusive combination of layered plastic and metal
material used for system calibration. It is equipped with handles and labeled with characterization values estab-
lished at the factory.
QC Phantom
The anatomically correct QC Phantom provides an accurate representation of the human spine bone density
and soft tissue distribution. Each phantom (unique for each system) has a serial number and includes a label
listing the assigned Bone Mineral Density (BMD), Bone Mineral Content (BMC), BMD Standard Deviation
(BMD SD), Fat Mass, Fat SD, Lean Mass, and Lean SD values as determined by factory characterization.
Refer to "Cleaning QC Phantom" on page 15-2 for special instructions.
Operator's Guide
437D140 Rev. I
2-6
General Information
Summary of Contents for Elite 437A150
Page 1: ...DXA Bone Densitometer Operator s Guide Elite Model 437A150 Operator s Guide 437D140 Rev I...
Page 22: ...This page intentionally left blank Operator s Guide 437D140 Rev I 1 8...
Page 56: ...This page intentionally left blank Operator s Guide 437D140 Rev I 2 34...
Page 66: ...11 Click Operator s Guide 437D140 Rev I 3 10 Installation and Setup...
Page 108: ...This page intentionally left blank Operator s Guide 437D140 Rev I 3 52...
Page 124: ...Sample Printed QA Results Report Operator s Guide 437D140 Rev I 4 16 Basic Operation...
Page 137: ...Operator s Guide 437D140 Rev I Basic Operation 4 29...
Page 166: ...This page intentionally left blank Operator s Guide 437D140 Rev I 5 24...
Page 198: ...Operator s Guide 437D140 Rev I 7 20 Scanning AP Spine...
Page 206: ...This page intentionally left blank Operator s Guide 437D140 Rev I 7 28...
Page 238: ...Figure 8 6 Page 2 of the Bone Exam Report Operator s Guide 437D140 Rev I 8 32 Scanning Hip...
Page 290: ...This page intentionally left blank Operator s Guide 437D140 Rev I 10 30...
Page 326: ...Operator s Guide 437D140 Rev I 11 36 Additional Techniques...
Page 412: ...This page intentionally left blank Operator s Guide 437D140 Rev I 14 16...
Page 428: ...This page intentionally left blank Operator s Guide 437D140 Rev I 16 10...
Page 446: ...Label Locations continued Operator s Guide 437D140 Rev I 17 18 Technical Reference...
Page 448: ...Scanner Labels continued Operator s Guide 437D140 Rev I 17 20 Technical Reference...
Page 449: ...Operator s Guide 437D140 Rev I Technical Reference 17 21 Scanner Labels continued...
Page 459: ...Operator s Guide 437D140 Rev I Reference Data Sets 18 9...
Page 466: ...Operator s Guide 437D140 Rev I This page intentionally left blank...
Page 484: ...Operator s Guide 437D140 Rev I This page intentionally left blank...