background image

3

TECHNICAL DATA

Article number

997 100 .. ..

997 180 .. ..

Lamp

OSRAM

®

 G36T8/OF HNS 36W G13

OSRAM

®

 G36T8/OF HNS 36W G13

Lamp service life

9000 h at +40 °C

9000 h at +40 °C

Wavelength

253.7 nm

253.7 nm

Air-flow rate

100 m³/h

180 m³/h

UV-C interference radiation

< 1 mW/m² according to DIN EN 
12198-1

< 1 mW/m² according to DIN EN 
12198-1

Flow velocity

Approx. 1 m/s

Approx. 1.75 m/s

Radiation (dose)

41 J/m²

24 J/m²

Air humidity,

 

non-condensing

5% to 85%

5% to 85%

Max. system power,

 

continuous operation

75 W

75 W

Protection class

I

I

Protection rating (IP)

IP 20

IP 20

Sound pressure level

20 db(A)

32 db(A)

Transformer

220–240 V AC, 50 Hz/60 Hz

220–240 V AC, 50 Hz/60 Hz

Ozone-free

Yes

Yes

Installation type

Wall mounting

Wall mounting

Dimensions (L x W x H)

1870 mm x 155 mm x 185 mm

1870 mm x 155 mm x 185 mm

Mounting spacing 
(mounting dimension)

1214 mm

1214 mm

Max. weight

11 kg

11 kg

Summary of Contents for BUENOS AIRES UV-C

Page 1: ...1 Operating instructions BUENOS AIRES UV C Wall mounting Article number 997 100 02 Article number 997 180 02...

Page 2: ...ildren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given su pervision or instruction concerning u...

Page 3: ...city Approx 1 m s Approx 1 75 m s Radiation dose 41 J m 24 J m Air humidity non condensing 5 to 85 5 to 85 Max system power continuous operation 75 W 75 W Protection class I I Protection rating IP IP...

Page 4: ...he wall bracket with the lamp control light pointing down wards towards the floor The spacer nut must be inside the recess of the wall bracket Tighten the fastening nut SW10 to 2 Nm Plug in the mains...

Page 5: ...5 Spacer nut Fastening nut SW 10...

Page 6: ...h off the air disinfection unit before maintenance Disconnect the air disinfec tion unit from the mains Never immerse the air disinfection unit in water or other liquids Do not use abrasive cleaners o...

Page 7: ...7 REPLACING THE UV C LAMP A Wait until the unit has cooled down completely B Remove the housing screws C Pull the lamps towards the housing opening C B...

Page 8: ...8 D Insert the new lamps type OSRAM HNS 36W G13 E Check whether the lamp is centred in the socket D E...

Page 9: ...UV C lamps No air flowing out of air outlet Air inlet blocked Check the air inlet Fan defective Please contact NORKA Customer Service Fan wheel is not turning al though green control lamp is on Fan w...

Page 10: ...devices is governed by national regulations based on the EU Directive 2012 19 EU on Waste Electrical and Electronic Equipment WEEE According to this Directive the unit or the UV C lamp must not be di...

Page 11: ...dards EU Declaration of Conformity Manufacturer Norddeutsche Kunststoff und Elektrogesellschaft St cker mbH u Co KG Lange Stra e 1 27313 D rverden H lsen Place Date Issuer Signed for and on behalf of...

Page 12: ...d Elektro gesellschaft St cker mbH Co KG Lichttechnische Spezialfabrik Weidestra e 122 a 22083 Hamburg Germany T 49 0 40 513 009 0 info norka com norka com 102515 V1 0 09 08 2021 Subject to technical...

Reviews:

Related manuals for BUENOS AIRES UV-C