No flame.
WARNING
Be sure
to do.
When a gas leak is noticed:
1. Stop use immediately
2. Close the gas valve
If you detect abnormal combustion
or abnormal odors, or during an
earthquake, tornado or fire:
1. Turn off the hot water supply
2. Turn off the power to the water
heater
3. Turn off gas and water supply valve
4. Call the nearest Noritz agent
Be sure
to do.
Do not allow anyone to change the water
temperature while hot water is being used.
To prevent scalding, do not change the
water temperature to a higher setting.
Prohibited
A. This water heater does not have
a pilot. It is equipped with an
ignition device that automatically
lights the burner. Do not try to
light the burner by hand.
B. BEFORE OPERATING smell all
around the water heater area for
evidence of leaking gas. Be sure
to smell next to the floor because
some gas is heavier than air and
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS.
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone
in your building.
• Immediately call your gas
supplier from a neighbor’s
phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to turn
the gas valve knob. Never use
tools. If the knob will not turn by
hand, don’t try to repair it. Call
a qualified service technician.
Force or attempted repair may
result in a fire or explosion.
D. Do not use this water heater if
any part has been under water.
Immediately call a qualified
service technician to inspect the
water heater and to replace any
damaged parts.
(Continued)
Check the temperature
of the running hot water
before entering the
shower.
Check the temperature
before stepping into
the bath tub.
High
Temperature.
Explosion Hazard ;
If the temperature and pressure relief
valve is dripping or leaking, have a
qualified service technician replace it.
Do not plug or remove the valve.
Failure to follow these instructions can result
in fire or explosion, and personal injury or
death.
Prohibited
Prohibited
Do Not Install Indoors.
This will cause carbon
monoxide poisoning and
a potential fire hazard.
Indoor
Do not place the exhaust vent terminal
in an indoor environment by means of
adding walls and ceiling (Do not enclose
using corrugated sheets, etc.)
Carbon monoxide poisoning or fire may
occur as a result.
Prohibited
Unit
Leave the proper clearance between
the water heater and nearby objects
(trees, timber, boxes with flammable
materials etc.).
Be sure
to do.
*
Indicates suggested clearances for maintenance.
Left side:
Min. 6" (150mm)
Right side:
Min. 6" (150mm)
Upper:
Min. 36" (900mm)
Front:
Sug. 24" (600mm)
*