![Noritz N-0751M-DVC Owner'S Manual Download Page 27](http://html.mh-extra.com/html/noritz/n-0751m-dvc/n-0751m-dvc_owners-manual_1705180027.webp)
27
Specification
NR98-DVC
Indoor, Wall Mounted
Power Vented
Direct Ignition
15-150 psi
0.5 GPM
23.6"(Height) x 13.8"(Width) x 10.2"(Depth)
55 lbs.
0.2 Gallon
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG : 108W LP : 96W Freeze Prevention 161W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Electric Leakage Prevention Device
(GFCI), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Anchoring Screws
Specifications
Specifications
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
45
°
F Rise
7.5 Gal./min.
0.5-9.8 Gal./min.
100-150
°
F (In 5
°
F intervals),
160, 170, 180
°
F (In 10
°
F intervals) (14 Options)
120,130,140,180
°
F (Original is 120
°
F)
Maximum Performance
199,900 btuh
199,900 btuh
Minimum Performance
11,000 btuh
11,000 btuh
Summary of Contents for N-0751M-DVC