26
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
7
°
C (45
°
F) Rise
26L/min. (6.9 Gal./min.)
2.7-30L/mon. (0.7-7.9 Gal./min.)
37-50
°
C (99-122
°
F) (In 1
°
C intervals),
55-80
°
C (131-176
°
F) (In 5
°
C intervals) (19 Options)
50, 55, 60 80
°
C (122,131,140,176
°
F)
(Original is 50
°
C (122
°
F))
Maximum Performance
194,000 btuh
194,000 btuh
Minimum Performance
25,000 btuh
25,000 btuh
Specification
N-069M-DV
Indoor Wall Hanging
Direct Vent/Sealed Combustion
15-150 PSI
2.7L/min. (0.7 GPM)
615mm (24.2") x 465mm (18.3") x 239mm (9.4")
63 lbs.
1.1L (0.3 Gallon)
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG:70W, LP:74W, Freeze Prevention 135W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR),
Electric Leakage Prevention Device (GFCI), Overheat
Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Specifications
Specifications
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
Direct Ignition
SAR8208̲014̲026̲E̲J.p65
05.11.29, 10:40 PM
Page 26
Adobe PageMaker 6.5J/PPC