![Noritz GQ-C3259WZ-FF US Owner'S Manual Download Page 36](http://html1.mh-extra.com/html/noritz/gq-c3259wz-ff-us/gq-c3259wz-ff-us_owners-manual_1705158036.webp)
36
Periodic Maintenance
If the water drain valve (with water filter) is covered with debris, the hot water may not run
smoothly, or the unit may put out cold water. Check and clean the filter as explained below.
* To avoid burns, wait until the equipment cools down before draining the water.
The appliance will remain hot after it is turned off.
Water Drain Valve (with Water Filter)
1. Close the water supply valve.
2. Open all hot water fixtures/faucets.
3. With a bucket ready, remove the inlet and outlet drain plugs (about 0.65 gallon (2.5 L) will drain out)
4. Take the water drain valve (with water filter) out of the inlet. (See illustration to below).
5. Clean the water drain valve (with water filter) with a brush under running water.
6. Replace the water drain valve (with water filter) and close the drain plugs.
(Take care not to lose the packing.)
7. Close all hot water fixtures/faucets.
8. Open the water supply valve and check that water does not leak from the drain plugs or water
drain valve (with water filter).
Water Supply Valve
Inlet
Packing
Water drain valve
(with water filter)