![Noritz GQ-2857WX US Owner'S Manual Download Page 4](http://html1.mh-extra.com/html/noritz/gq-2857wx-us/gq-2857wx-us_owners-manual_1705148004.webp)
4
Do not place the unit or the exhaust vent
terminal in an indoor environment by
means of adding walls and ceiling (Do not
enclose using corrugated sheets, etc.)
Carbon monoxide poisoning or fire may
occur as a result.
Important Safety Information
-
2
(Continued)
If this unit will be installed in a
location where hair spray or aerosols
will be used, locate the unit in a
separate area that is supplied with
fresh air from outdoors
.
Prohibited
Be sure the gas/power
supplied matches the
gas on the rating plate.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Be sure
to do.
Be sure
to do.
(Continued)
Prohibited
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Prohibited
Do not place or use a spray can near
the water heater or the exhaust vent
terminal.
Do not use hair spray or spray
detergent in the vicinity of the
heater.
Prohibited
Prohibited
Leave the proper clearance between
the water heater and nearby objects
(trees, timber, boxes with flammable
materials etc.).
Be sure
to do.
*
Indicates suggested clearances for maintenance.
Do not place combustibles such as
laundry, newspapers, oils etc. near
the heater
or the exhaust vent terminal.
Prohibited
Do not use combustible chemicals such
as oil, gasoline, benzene etc. in the near
the heater or the exhaust vent terminal.
Prohibited
[NR98SV]
Carbon Monoxide Poisoning Hazard.
Do not install this water heater in a mobile
home, recreational vehicle or on a boat.
Prohibited
WARNING
Unit
Left side:
Min. 6" (150mm)
Right side:
Min. 6" (150mm)
Upper:
Min. 36" (900mm)
Front:
Sug. 24" (600mm)
*
Unit
Ex. For Natural Gas
(NR98OD (GQ-2857WX US))
[NR98DVC, NR98SV]
Do not place outdoors
Rain may enter the unit or the
burner fire may be blown by the
wind, causing malfunction or fire
as a result.
Prohibited
Outdoor
Left side:
Min. 2" (50mm)
Right side:
Min. 2" (50mm)
Front:
Sug. 24" (600mm)
*
Sug. 3" (75mm)
from vent pipe*
Upper: Min.
12" (300mm)
[NR98OD]
[NR98DVC, NR98SV]
Exhaust vent
terminal
Exhaust vent
terminal
[NR98OD, NR98DVC]
Carbon Monoxide Poisoning Hazard.
Do not install this water heater in a
recreational vehicle or on a boat.
Prohibited
Summary of Contents for GQ-2857WX US