8.

 Water Piping

This appliance is suitable for combination potable water and space heating applications. It cannot be used for space 

heating applications only. Do not use this appliance if any part has been underwater.  Immediately call a qualified 

service technician to inspect the appliance and replace any part of the control system and gas control which has 

been under water.

If the water heater is installed in a closed water supply system, such as one having a backflow preventer in the 

cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or a local 

plumbing inspector on how to control this situation.
A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying 

with either The Standard for Relief Valves and Automatic Shutoff Devices for Hot Water Supply Systems, ANSI 

Z21.22, or The ANSI/ASME Boiler and Pressure Vessel Code, Section IV ( Heating Boilers ). This pressure relief 

valve must be capable of an hourly Btu rated temperature steam discharge of 140,000 Btuh. Multiple valves may be 

used. The pressure relief capacity must not exceed 150 psig. No valve shall be placed between the relief valve and 

the water heater. The relief valve must be installed such that the discharge will be conducted to a suitable place for 

disposal when relief occurs. No reducing coupling or other restriction may be installed in the discharge line. The 

discharge line must be installed to allow complete drainage of both the valve and the line. If this unit is installed with 

a separate storage vessel, the separate vessel must have its own temperature and pressure relief valve. This valve 

must also comply with The Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply 

Systems, ANSI Z21.22. (in the U.S. only). A temperature relief valve is not required, but if one is used, do not install 

the valve with the probe directly in the flow of water. This may cause unwarranted discharge of the valve.

Piping and components connected to the water heater shall be suitable for use with potable water.

Toxic chemicals, such as those used for boiler treatment, shall not be introduced into the potable water.

A water heater used to supply potable water may not be connected to any heating system or components previously 

used with a nonpotable water heating appliance.

When water is required in one part of the system at a higher temperature than in the rest of the system, means 

such as a mixing valve shall be installed to temper the water to reduce the scald hazard.

Installation and service must be performed by a qualified plumber.  In the 

Commonwealth of Massachusetts, this product must be installed by a licensed 

plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel 

Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes.

•  Flush water through the pipe to clean out metal powder, sand and dirt before connecting it.

•  Perform the following insulation measures for prevention of freezing. 

-  Take appropriate heat insulation measures (e.g., wrapping with heat 

insulation materials, using electric heaters) according to the climate 

of the region to prevent the pipe from freezing.

-  Make sure that there are no water leaks from the cold and hot water 

supply pipes, then insulate the pipes completely. 

- Be sure to also completely insulate the water supply valve and the 

cold and hot water connections on the water heater (refer to the fig

-

ure on the right).  

-  Do not cover the water drain plug with insulation so that water in the 

pipe can be drained. (Refer to the figure in the right.)  

• 

Use a union coupling or flexible pipe for connecting the pipes to reduce the force applied to the piping.

•  Do not use piping with a diameter smaller than the coupling.

•  When feed water pressure is too high, insert a depressurizing valve, or take water hammer prevention measure.

•  Avoid using joints as much as possible to keep the piping simple.

•  Avoid piping in which an air holdup can occur.

•  If installing the unit on a roof:

•  About lower-level hot water supply

  If the unit is installed on a roof to supply water to the levels below, make sure that the water pressure supplied 

to the unit does not drop below 29 psi. It may be necessary to install a pump system to ensure that the water 

pressure is maintained at this level.

  Check the pressure before putting the unit into operation.

  Failure to supply the proper pressure to the unit may result in noisy operation, shorter lifetime of the unit, and 

may cause the unit to shut down frequently.

Completely insulate 

the water inlet and 

outlet fittings.

Insulate the water 

supply valve completely.

Do not cover the water 

drain plug with insulation 

so that water in the pipe 

can be drained.

Summary of Contents for GQ-2039WS ET US

Page 1: ...ater heater safely read this installation manual carefully and follow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not cover...

Page 2: ...cessories listed below are not included with the units but may be necessary for installation Cross Recessed Head Screw Q ty Shape Part Part Shape Q ty 1 Remote Controller Cord 26ft 8m 1 Isolation Valv...

Page 3: ...nce The pan must not restrict combustion air flow As with any water heating appliance the potential for leakage at some time in the life of the product does exist The manufacturer will not be responsi...

Page 4: ...ous materials or corrosion of aluminum materials Do not locate the vent termination directed towards a window or any other structure which has glass or wired glass facing the termination Install in a...

Page 5: ...the unit in a location where the unit is out of reach such as the wall of the second floor When installing the unit in a common side corridor provide a clearance of 47 1 190mm or more in front of the...

Page 6: ...de 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwelling...

Page 7: ...o not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locati...

Page 8: ...ons or concerns CAUTION Regulators Ensure that all gas regulators used are operating properly and providing gas pressures within the specified range of the water heater being installed Excess gas inle...

Page 9: ...ing to total btuh demand of the building and length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC...

Page 10: ...let C Outlet D Outlet E Section 4 Table 2 For 8 WC 10 5 WC initial supply pressure Maximum Natural Gas Delivery Capacity 3 0 Pressure Drop Values in Table are in Cubic Feet of Gas per Hour 0 60 Specif...

Page 11: ...nce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION P...

Page 12: ...be connected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest of...

Page 13: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Page 14: ...Guidelines If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to...

Page 15: ...hed If the error code C is displayed and flashing in the Display Window please contact Noritz America 855 960 3434 Connect the blue connector marked FLUSH for flushing on the Circuit Board when flushi...

Page 16: ...pump The flushing solution needs to be rinsed and cleaned out of the water heater Below is the way to rinse and clean the flushing solution 1 Remove both drain hoses H2 and H3 from the bucket And the...

Page 17: ...essary to prevent cycling 5 If the system requires water for space heating at a higher temperature than for other uses means such as a mixing valve shall be provided to temper the water for the other...

Page 18: ...The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 182W Use an appropriate circuit Do not disconnect the power supply when not in use When the po...

Page 19: ...ter back into operation press the Power On Off Button on the optional remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When changing the tem...

Page 20: ...by pressing the Power On Off Button on the remote controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the Flow Meter Alarm Set Button and hold it in for 2 seconds or mo...

Page 21: ...ation air The pressure relief valve must be operated once a year to ensure that it is functioning properly and there is no obstruction Turn the power off to the unit before opening the relief valve an...

Page 22: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Page 23: ...7mm 1 6 40mm 2 0 50mm 3 3 85mm 4 7 120mm 0 4 10mm 0 4 10mm 21 3 542mm 19 2 487mm 1 2 31mm 3 0 3 0 6 6 5 16 5mm OBLONG HOLE 2 0 3 0 5 6 5 13mm OBLONG HOLE HEIGHT OF EACH FITTING FROM BOTTOM OF CASE mm...

Page 24: ...Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations where special chemi...

Page 25: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Page 26: ...l pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wall Wal...

Reviews: