background image

Potential dangers from accidents during installation and use are divided into the following three 

categories. Closely observe these warnings, they are critical to your safety.

Prohibited

Disconnect

Power

Ground

Be sure to do

WARNING:

 If the information in this manual is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

NORITZ AMERICA 

CORPORATION

 Installation Manual

CONDENSING TANKLESS GAS WATER HEATER

                            NRC711-OD

 

(Outdoor Installation)

                            NRC661A-OD

 

(Outdoor Installation)

DANGER indicates an imminently hazardous situation which, 

if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, 

if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, 

if not avoided, may result in minor or moderate injury.

DANGER

WARNING

CAUTION

SBB8068-2

Rev. 08/15

Requests to Installers

•  In order to use the water heater safely, read this installation manual carefully, and follow the in-

stallation instructions.

•  Failures and damage caused by erroneous work or work not as instructed in this manual are not 

covered by the warranty.

•  Check that the installation was done properly in accordance with this Installation Manual upon  

completion.

• 

After completing installation, please either place this Installation Manual in a plastic pouch and 

attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable), 

or hand it to the customer to retain for future reference.  Also, be sure to fill in all of the required 

items on the warranty and to hand the warranty to the customer along with the Owner's Guide.

CAUTION

Low NOx Approved by SCAQMD

14 ng/J or 20 ppm 

(Natural Gas Only)

*SBB8068*

FOR USE IN RESIDENTIAL OR MANUFACTURED HOME

APPLICATIONS.
Installation  must  conform  with  local  codes,  or  in  the  absence  of 

local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54- 

latest edition.

When applicable, installation must conform with the Manufactured 

Home Construction and Safety Standard, Title 24 CFR, Part 3280.

Noritz America reserves the right to discontinue, or change at any 

time, the designs and/or specifications of its products without notice.

Summary of Contents for ecoTOUGH NRC661-OD-LP

Page 1: ...y and follow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty Check that the installation was done p...

Page 2: ...d below are not included with the units but may be necessary for installation Cross Recessed Head Screw Q ty Shape Part Part Shape Q ty 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pre...

Page 3: ...the water supply as unexpected accidents may occur as a result Check Water Supply Quality If the water supply is in excess of 12 grains per gallon 200 mg L of hardness acidic or otherwise impure trea...

Page 4: ...e surrounding trees and animals The heat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminum materials Do not locate the vent terminatio...

Page 5: ...nstall the unit such as the wall of the second floor where the unit is out of reach When installing the unit in a common side corridor provide a clearance of 47 1 190mm or more in front of the unit Se...

Page 6: ...rance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance K Clearance to a mechanical air supply inlet L Clear...

Page 7: ...o not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locati...

Page 8: ...er heater as with any gas appliance is the sole responsibility of the installer The installer must be professionally trained to do such work and must always follow all local and national codes and reg...

Page 9: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Page 10: ...Btuh NRC661A OD series 120 000 Btuh Table 2 For 8 WC 10 5 WC initial supply pressure Maximum Natural Gas Delivery Capacity 3 0 Pressure Drop Values in Table are in Cubic Feet of Gas per Hour 0 60 Spec...

Page 11: ...all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION Pipe Size Leng...

Page 12: ...upply potable water may not be connected to any heating system or components previ ously used with a nonpotable water heating appliance When water is required in one part of the system at a higher tem...

Page 13: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Page 14: ...ng and form If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to...

Page 15: ...15 the Heat Exchanger must be flushed is set to Flushing Mode from an authorized Noritz wholesaler...

Page 16: ...16 located...

Page 17: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 0 8 GPH from the water heater Horizontal runs must be slo...

Page 18: ...n of piping and form Condensate piping to floor drain Condensate piping with pump Slope pipe downwards 1 4 per foot or more The end of the drain pipe must have an air gap 1 or more USE NON CORROSIVE M...

Page 19: ...include an integrated shut off and service valve with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated sh...

Page 20: ...The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 182W Use an appropriate circuit Do not disconnect the power supply when not in use When the po...

Page 21: ...er heater back into operation press the Power On Off Button on the optional remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When changing t...

Page 22: ...On Off Button Flow Meter Alarm Set buttton Setting Button Remote Controller Setting Procedure 1 Turn the water heater off by pressing the Power On Off Button on the remote controller 2 Disconnect the...

Page 23: ...efore opening the relief valve and make sure that water draining out of the valve will not cause any damage If the relief valve discharges periodically it may be due to thermal expansion in a closed w...

Page 24: ...s stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate w...

Page 25: ...90mm 3 0 3 0 6 6 5 16 5mm OBLONG HOLE 4 0 5 13mm WATER DRAIN VALVE HOT WATER OUTLET CONDENSATE DRAIN WATER DRAIN VALVE COLD WATER INLET WIRING THROUGHWAY GAS INLET AC120V WATER DRAIN VALVE WATER FILT...

Page 26: ...Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations where special chemi...

Page 27: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Page 28: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Reviews: