Noritz ecOTOUGH NRC1111-DV-LP Installation Manual Download Page 15

15

Vertical Vent Termination- PVC/CPVC Materials Only

Horizontal Vent Termination- PVC/CPVC Materials Only

Insert Bird
Screen* in
End of Each
90  Elbow

Hanger

Straps

**1' mini

* Not supplied with water heater, 
  order separately.

mum recommended,

but not required. 

 3 ft. Min.

3 ft. Min.

Firestop

Firestop

Firestop/Support

Roof
Flashing

Roof

Flashing

Hanger

Strap

**1' 
Minimum

**1'
Minimum

Support

Slope 

Slope vent

Upwards

Intake

Exhaust

vent

Upwards

Intake

Exhaust

Insert Bird Screen* 
in End of 45   Elbow

12" over maximum
snow level
or 24", whichever
is greater.

12" over maximum
snow level
or 24", whichever
is greater.

Insert Bird 
Screen* in
End of 
90  Elbow 

Storm
Collar

Storm
Collar

As illustrated on the left, make sure to keep a 
distance of 3' (0.9m) or wider between the intake and 
exhaust when installing the vent piping.

The PVT-HL termination may be used in place of elbows
as the horizontal vent terminations. It is not necessary to
use bird screens with the PVT-HL termination.

Terminate at least 12" (300mm) above grade or above 
snow line.

Terminate at least 7' (2.1m) above a public walkway,
6' (1.8m) from the combustion air intake of any 
appliance, and 3' (0.9m) from any other building 
opening, gas utility meter, service regulator etc.

Terminate at least 3' (0.9m) above any forced air inlet 
within 10' (3m) , 1' (0.3m) below, 1' (0.3m) horizontally
from or 1' (0.3m) above any door, window, or gravity 
air inlet into any building per National Fuel Gas Code 
ANSI Z223.1/NFPA 54.

Slope the horizontal vent 1/4" upwards for every 
12" (300mm) toward the termination.

Use a condensation drain if necessary.

In the Commonwealth of Massachusetts a carbon 
monoxide detector is required for all side wall  
horizontally vented gas fuel equipment. 
Please refer to Technical Bulletin TB 010606 for
full installation instructions.

As illustrated on the left, make sure to keep a distance 
of 3' (0.9m) or wider between the intake and exhaust 
when installing the vent piping.

Terminate at least 6' (1.8m) from the combustion air
intake of any appliance, and 3' (0.9m) from any other 
building opening, gas utility meter, service regulator etc.

Enclose exterior vent systems below the roof line to limit 
condensation and protect against mechanical failure.

When the vent penetrates a floor or ceiling and is not 
running in a fire rated shaft, a firestop and support is 
required.

When the vent termination is located not less than 
8' (2.4m) from a vertical wall or similar obstruction, 
terminate above the roof at least 2' (0.6m), but not 
more than 6' (1.87m), in accordance with the National 
Fuel Gas Code ANSI Z223.1/NFPA 54.

Provide vertical support every 3' (0.9m) or as required 
by the vent pipe manufacturer's instructions.

A short horizontal section is recommended to prevent 
debris from falling into the water heater.

When using a horizontal section, slope the horizontal 
vent 1/4” upwards for every 12” (300mm) toward the 
termination to drain condensate.

**1' minimum recommended,
but not required. 

* Not supplied with water heater, 
  order separately.

Vent Pipe Installation

Summary of Contents for ecOTOUGH NRC1111-DV-LP

Page 1: ...work not as instructed in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing instal...

Page 2: ...Shape Q ty Remote Controller Cord 26ft 8m Quick Connect Cord QC 2 1 1 1 each Isolation Valves includes pressure relief valve Owner s Guide Warranty Installation Manual this document Bird Screen for 4...

Page 3: ...ater temperature will become unstable as the pipe length increases Distance at center 20 3 36 3 in 515 922mm Quick Connect Cord Union Gas Valve Union Shutoff Valve Shutoff Valve Hot Water Shutoff Valv...

Page 4: ...ith a Solar Pre Heater Using this unit with a solar pre heater can lead to unpredictable output temperatures and possibly scalding If absolutely necessary use mixing valves to ensure output temperatur...

Page 5: ...s a result Avoid installation in places where special chemical agents e g hair spray or spray detergent are used Ignition failures and malfunction may occur as a result Carbon Monoxide Poisoning Hazar...

Page 6: ...nal noises while it is running Before installing make sure that the exhaust flue termination will have the proper clearances according to the National Fuel Gas Code ANSI Z223 1 State of California The...

Page 7: ...f the unit to facilitate maintenance and service if necessary If possible leave 3 75mm or more above and below the vent pipe to facilitate inspection and repair if necessary Securing of space for repa...

Page 8: ...k Illustration Outdoor Clearances to Opening into Any Building 12 300mm or more 12 300mm or more There must be no building opening within this area Flue terminal 12 300mm or more 12 300mm or more Vent...

Page 9: ...aintain clearances in accordance with local installation codes and the requirements of the gas supplier A vent shall not terminate directly above a sidewalk or paved driveway that is located between t...

Page 10: ...parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locating Screw Holes Mounting Structure When installing with bare hands take cauti...

Page 11: ...haust accessory on the top of the appliance as illustrated below Or if the vent pipe has already been installed 2 After installing the drain pipe make sure that the area around the appliance is well v...

Page 12: ...ill not produce an exhaust flue temperature in excess of 149 F 65 C and schedule 40 PVC pipe may be used as the vent material If required by local code schedule 40 or 80 CPVC may also be used on this...

Page 13: ...18 00 18 90 m 1 0 2 3 4 ft Vent length Elbows 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Number of pieces 3 3 0 3 3 5 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 3 3 0 3 3 5 3 3 3 3 3 3 3 4...

Page 14: ...arely cut all pieces of pipe o Remove all burs and debris from joints and fittings o All joints must be properly cleaned primed and cemented Use only cement and primer approved for use with the pipe m...

Page 15: ...National Fuel Gas Code ANSI Z223 1 NFPA 54 Slope the horizontal vent 1 4 upwards for every 12 300mm toward the termination Use a condensation drain if necessary In the Commonwealth of Massachusetts a...

Page 16: ...public walkway 6 1 8m from the combustion air intake of any appliance and 3 0 9m from any other building opening gas utility meter service regulator etc T erminate at least 3 0 9m above any forced ai...

Page 17: ...r must be supplied from the outdoors as shown on pages 15 16 Terminate at least 6 1 8m from the combustion air intake of any appliance and 3 0 9m from any other building opening gas utility meter serv...

Page 18: ...ance in front of the unit to the door If combustion air will be provided through a duct size the duct to provide 60 cubic feet of fresh air per minute Supply combustion air to the units as per the Nat...

Page 19: ...1 Natural Gas Meter See next page for the pipe capacity charts Noritz Condensing Tankless Gas Water Heater 199 900 Btuh Clothes Dryer 35 000 Btuh Barbecue 50 000 Btuh Gas Range Stove 65 000 Btuh 10 3...

Page 20: ...496 55 112 213 440 675 1260 Maximum Capacity of Flex TracPipe in Cubic Feet per Hour of Natural Gas 0 60 Specific Gravity 0 5 WC Pressure Drop Length in Feet Pipe Size 3 4 1 1 1 4 1 1 2 2 206 383 614...

Page 21: ...ater may not be connected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in...

Page 22: ...eans to ensure that the supply water pressure to the inlet of the heater does not fall below 29 PSI when the maximum amount of water is being demanded Also install a pressure meter on the inlet If thi...

Page 23: ...Required Treatment Required Install Noritz Isolation Valves to allow for flushing Flushing is required if a water treatment device is not installed Suggested Suggested Install Noritz Isolation Valves...

Page 24: ...Long runs or applications where the nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 2 GPH from the water...

Page 25: ...PVC pipe DO NOT ADD ANY VALVES NORITZ Condensing Tankless Gas Water Heater DO NOT ADD ANY VALVES NORITZ Condensing Tankless Gas Water Heater Note If the drain line becomes clogged or frozen condensate...

Page 26: ...0 F 5 C below the set output temperature 4 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a pressure re...

Page 27: ...eater will not activate resulting in possible freezing damage Do not let the power cord contact the gas piping Tie the redundant power cord outside the water heater Putting the redundant length of cor...

Page 28: ...o operation press the Power On Off Button on the remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display This unit can be programmed so that it wil...

Page 29: ...the end of the remote controller cord to the terminal block 5 Replace the terminal block cover and install the screw previously removed in step 3 6 Reconnect electrical power to the water heater Exter...

Page 30: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Connect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Page 31: ...pling Cord Clamp Ground wire Connector Connector Connecting Quick Connect Cord 2 Caution For Quick Connect Multi System Installation use part QC 2 only sold separately Quick Connect Cord 2 Quick Conne...

Page 32: ...r a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do...

Page 33: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Page 34: ...S INLET COLD WATER INLET HOT WATER OUTLET CONDENSATE DRAIN FROM BOTTOM OF CASE HEIGHT OF EACH FITTING 6 7 170mm 5 5 140mm 3 9 100mm 2 8 70mm 1 4 36mm 0 4 10mm 4 0 5 13mm 6 0 24 x 0 4 6 x 10mm OBLONG H...

Page 35: ...on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations...

Page 36: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Page 37: ...ual provided with the water heater In order to use this product safely read this installation manual carefully and follow the installation instructions Potential dangers from accidents during installa...

Page 38: ...t The value in indicates the quantity Remote Controller Mounting bracket Raised countersunk head wood screw Wall anchor Raised countersunk head screw For junction box installation Machine screw When a...

Page 39: ...mounting bracket Insert the bottom of the remote contoller into the groove at the bottom of the bracket and push in the 2 hooks on top of the remote controller completely If it is difficult to attach...

Page 40: ...tons 3 Press the ENTER Button the Misc settings screen appears on the display 4 Select Max set Temp using the Buttons 5 Press the ENTER Button 120 F 50 C appears on the display 6 Set the upper limit o...

Page 41: ...e controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the MENU Button inside the cover select Initial settings using the Buttons 4 Press the ENTER button the Initial se...

Reviews: