Noritz cCS-V Installation And Operating Instructions Manual Download Page 3

3

1. Limited warranty

The Noritz Crossover Valve Kit is warranted to the original user only to be

free of defects in material and workmanship for a period of 24 months from 

date of installation, but not more than 30 months from date of manufacture. 

Noritz’ liability under this warranty shall be limited to repairing or replacing at 

Noritz’ option, without charge, FOB Noritz.

 

Noritz will not be liable for any costs of removal, installation, 

transportation, or any other charges which may arise in connection with a 

warranty claim. Products which are sold but not manufactured by Noritz

are subject to the warranty provided by the manufacturer of said products and 

not by Noritz’ warranty. Noritz will not be liable for damage or wear to 

products caused by abnormal operating conditions, accident, abuse, misuse, 

unauthorized alteration or repair, or if the product was not installed in accord-

ance with Noritz’ printed installation and operating instructions.
To obtain service under this warranty, the defective product must be returned 

to the distributor or dealer of Noritz’ products from which it was purchased 

together with proof of purchase and installation date, failure date, and support-

ing installation data. Unless otherwise provided, the distributor or dealer will 

contact Noritz for instructions.
Any defective product to be returned to Noritz must be sent freight prepaid; 

documentation supporting the warranty claim and/or a Return Material  

Authorization must be included if so instructed.

NORITZ WILL NOT BE LIABLE FOR ANY

 

 

  INCIDENTAL OR CONSEQUENTIAL

 

 

DAMAGES, LOSSES, OR EXPENSES  ARISING FROM INSTALLATION, USE

OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED 

 

 

 

 WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR 

A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRAN-

TIES DESCRIBED OR REFERRED TO ABOVE.
Some jurisdictions do not allow the exclusion or limitation of incidental or con-

sequential damages and some jurisdictions do not allow limit actions on how 

long implied warranties may last. Therefore, the above limitations or exclusions 

also have other rights which vary from jurisdiction to jurisdiction.

Summary of Contents for cCS-V

Page 1: ...SKU cCS V INSTRUCTIONS Crossover Valve Kit Hot water recirculation valve Installation and operating instructions...

Page 2: ...cepted codes of good practice For programing please refer to the water heater s installation manual for additional set up information 1 Limited warranty 3 2 Symbols used in this document 4 3 Product i...

Page 3: ...tain service under this warranty the defective product must be returned to the distributor or dealer of Noritz products from which it was purchased together with proof of purchase and installation dat...

Page 4: ...nual Warning This is not an anti scald device After installation you may the valve is installed Once the cold water line is opened the warm water will dissipate in a very short time Warning For indoor...

Page 5: ...available 4 Installation Warning on the valve threads Warning turn with wrench can result in valve damage causing valve to leak and or localized water damage Warning When making piping connections be...

Page 6: ...er 4 2 Disconnecting the risers 1 Close both the hot and cold water angle stop valves below the sink 2 Fig 1 Close hot and cold water angle stop valves under the sink before installing the thermal byp...

Page 7: ...ort on the crossover valve 6 7 Open both hot and cold water angle stop valves Check for leaks 8 Crossover valve may be mounted to the wall with screws if 9 For troubleshooting see section Mounting har...

Page 8: ...ardware not included 1 2 x 3 8 1 2 x 3 8 Hot water IN Cold water IN Crossover valve Hot water OUT Cold water OUT 1 2 x 3 8 1 2 x 3 8 To hot water faucet To cold water faucet Correct Incorrect crossove...

Page 9: ...temp 170 F 76 C System installation type Open residential potable Max working pressure 145 psi 10 bar Max liquid temperature 140 F 60 C Min liquid temperature 36 F 2 C Connections 1 2 NPSM 5 1 Approv...

Page 10: ...review crossover valve installation instructions If necessary reinstall crossover valve For installation procedure see section 4 Installation 7 Disposal This product or parts of it must be disposed of...

Page 11: ...11...

Page 12: ...12 99675079...