Norgren 20AG Installation & Maintenance Instructions Download Page 1

Our policy is one of continued research and development. We therefore reserve the right to amend,  

without notice, the specifications given in this document. © 2020 Norgren Ltd

12/20

1

2

3

5

7

8

9

18

14

15

13

12

11

10

17

16

4

6

Technical data 

Fluid: Compressed air
Maximum pressure: 28 bar
Regulator type: Relieving or non-relieving diaphragm
Operating temperature: 

 

Gauge: -20° to +65°C

 

No gauge: -20° to +80°C

Air supply must be dry enough to avoid ice formation 
at temperatures below +2°C.
Main port size: 1/2", 3/4", 1"
Main port thread form: PTF or ISO G
Gauge ports:

 

1⁄8 PTF with PTF main ports

 

Rc1/8 with ISO G main ports

Outlet pressure adjustment ranges:**

 

0.1 to 3.5 bar

 

0.2 to 8.0 bar

 

0.7 to 17 bar (1/2" only)

**  Outlet pressure can be adjusted to pressures in excess of, 
 

and less than, those specified. Do not use these units to 

 

control pressures outside of the specified ranges.

Typical flow with 7 bar inlet pressure, 4 bar set 
pressure, and a 1 bar droop from set:

 

1/2" ports: 60 dm3/s , 3/4" ports: 80 dm3/s,

 

1" ports: 100 dm3/s

Materials:

 

Body: Zinc

 

Bonnet: Aluminum

 

Valve: Brass and nitrile

 

Valve seat: Brass

 

Elastomers: Nitrile

Bottom plug:

 

1/2" ports: Glass filled Nylon

 

3/4" and 1" ports: Aluminium

Replacement Items

Service kits (includes items circled on exploded view)
1/2" Ported Regulators:

 Relieving ............... 20AG-X4-100

 Non-relieving ....... 20AG-4-100
3/4" and 1" Ported Regulators:

 Relieving ............... 20AG-X8-100

 Non-relieving ....... 20AG-8-100

Installation

1.  Shut off air pressure. Install regulator in air line 

   •  with air flow in direction of arrow on body

   •  upstream of lubricators and cycling valves

   •  as close as possible to the device being serviced

   •  at any angle
2. Connect piping to proper ports using pipe thread 

sealant on male threads only. Do not allow 

sealant to enter interior of regulator.

3. Install a pressure gauge or plug the gauge ports. 

Gauge ports can also be used as additional 

outlets for regulated air.

4. Install a Norgren general purpose filter upstream 

of the regulator.

Adjustment

1.  Before applying inlet pressure to regulator, turn 

adjustment (1) counterclockwise to remove all 

force on regulating spring (6).

2. Apply inlet pressure, then turn adjustment (1) 

clockwise to increase and counterclockwise to 

decrease pressure setting.

3.  Always approach the desired pressure from a 

lower pressure. When reducing from a higher to a 

lower setting, first reduce to some pressure less 

than that desired, then bring up to the desired 

pressure.

Note

With non-relieving regulators, make pressure reductions with 

some air flow in the system. If made under no flow (dead-

end) conditions, the regulator will trap the over-pressure in 

the downstream line.

4. Tighten lock nut (2) to lock pressure setting.

Disassembly

1. Regulator can be disassembled without removal 

from air line.

2. Shut off inlet pressure. Reduce pressure in inlet 

and outlet lines to zero.

3. Turn adjustment (1) counterclockwise to remove 

all force on regulating spring (6).

4. Disassemble in general accordance with the 

item numbers on exploded view. Do not remove 

valve seat (14) unless replacement is necessary. 

Remove o-ring (8) using a hook shaped tool, 

taking care not to damage o-ring seating 
surfaces and valve seat.

20AG Pressure Regulator

Installation & Maintenance Instructions