17-6900-01

CONTACT INFORMATION

Congratulations on selecting Norfield Industries for your woodworking machinery solutions.  A factory 
Service Representative will be contacting you to review the site pre-installation requirements, and to 
discuss the shipping schedule of your machine. Thereafter, our factory trained Field Engineer will 
contact you to schedule the machine setup and training. 

If you have questions regarding site preparations, or anticipate delays that will effect the installation, 
please call the Norfield  Service Department at 800-824-6242.

SITE PREPARATION BEFORE MACHINE ARRIVES

1 . Ve r i f y   E l e c t r i c a l , A i r,  a n d   S p a c e   R e q u i re m e n t s 

Use the Table in the attached drawing (6815-001) to verify the Electrical and Air requirements.

A . )   Fo r   E l e c t r i c a l   R e q u i re m e n t s

1. For the 3-Phase power, E1, select your machine 3-Phase voltage con

fi

 guration, either 208V/230V or 

460V, and use the values in that row to verify the requirements. 

2. The Single-Phase requirement is the same for both con

fi

 gurations.

3.  If new electrical power to the machine will be needed, only a quali

fi

 ed electrician should complete 

the installation.   A 3-Phase circuit and a separate  230 volt Single-Phase circuit, including neutral 

and earth ground is required.

Do Not

 

pull the 230 Single-Phase circuit from the 3-Phase circuit at the machine !

B . )   Fo r  A i r   R e q u i re m e n t s

1. If new air lines will be installed the pipe size can be no smaller than 3/8”.  Pipe sizes will vary 

depending on the length of the run. Check the table for the correct size.

2. Use the dimensions in the attached drawing (6815-001) to verify the space requirements for the 

machine.

C . )   Fo r   S p a c e   R e q u i re m e n t s

1. Overall Length, 17ft. 1-1/2 inches, Width, including elevator motor, 48”, Height, 109” .
2. Clearance for service access, material 

fl

 ow (In & Out) should be considered when determining your 

space requirements.

  a. For Service Access, behind the machine, three (3ft) feet minimum, preferably four (4ft) feet.
  b. For Material Flow (In & Out) minimum eight (8ft) feet. 
3. If a standalone vacuum system will be used (not in-house system), use 3ft. x 5ft. dimensions for 

determining space requirements.  

1

Magnum Pre-install Guide 230V & 460V 