Bracket -

Left

Relay Box

Bracket -Right

Relay Box

Bracket 

- Right

Bracket

- Left

Figure 3.  Relay Box Installation 

MGHA & MMHA Only

p/n 903092A, 2-wire relay 

p/n 902898A, A/C Heat Pump 

(4-7 wire) relay box

Relay Box

Bracket 

Table 2. Three and Four Speed Blower Speed Selec-

tion for MG & MM - 05 Models

Table 2A. Blower Speed Selection M1 Models

Blower Speed Selection Chart 

For use with Blower Kit No. 902809

Furnace Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024, 030

036

042, 046 & 

048

086

M*

M*

H

H

070, 075, 077

L**

M*

H

H

056, 066, 070

L**

M*

H

H

*MH on Relay Box circuit board.
**ML on Relay Box circuit board.

Blower Speed Selection Chart 

For use with Blower Kit No. 902809

Furnace Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024, 030

036

042, 046 & 

048

086

M*

M*

H

H

070, 075, 077

L**

M*

H

H

056, 066, 070

L**

M*

H

H

Blower Speed Selection Chart 

For use with Blower Kit No. 903412 1/3 HP 2 Speed

Furnace Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024

036 & 030

077, 086, 090

H

ML*

H

056, 066, 070

ML*

ML*

H

*ML on Relay Box circuit board is low speed.

Blower Speed Selection Chart 

For use with Blower Kit No. 903413   1/2 HP 4 Speed

Furnace 

Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024

030 & 

036

042

048

077, 086, 090

ML

ML

ML

MH

H

056, 066, 070

L

ML

ML

MH

H

Blower Speed Selection Chart 

For use with Blower Kit No. 903414   3/4 HP 4 Speed

Furnace 

Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024

030 & 

036

042

048

077, 086, 090

ML

ML

ML

MH

H

056, 066, 070

L

ML

ML

MH

H

Blower Speed Selection Chart 

For use with 3 Ton 3 Speed Blowers

Furnace Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

024

030

036

056

L**

L**

M*

H

066, 070, 077

M*

L**

M*

H

086, 090

H

L**

M*

H

**L is ML on circuit board.
*M is MH on circuit board.

Summary of Contents for MGHA Series

Page 1: ...stallation Specifications or designs are subject to change or to discontinuance without notice and without incurring obligations These instructions are primarily intended to assist qualified individua...

Page 2: ...blower using the two self tapping screws provided The thermostat terminations should be towards the top of the furnace The furnace door should not interfere with the relay box Reattach the relay box...

Page 3: ...6 M M H H 070 075 077 L M H H 056 066 070 L M H H Blower Speed Selection Chart For use with Blower Kit No 903412 1 3 HP 2 Speed Furnace Input Heating Speed Setting Cooling Speed Evap Coil 024 036 030...

Page 4: ...pump only Set the furnace fan switch to AUTO the thermostat system switch to EMERGENCY HEAT and the thermostat fan switch to AUTO CONTINUOUS AIR CIRCULATION Set the thermostat fan switch to ON SHUT OF...

Page 5: ...5 Figure 6 A C Heat Pump Relay Box Exploded View Model p n 902898A Model p n 903092A AUTO FAN ON COOL OFF HEAT 6 3 8 4 1 7 2 9 5 Figure 5 2 Wire Relay Box Exploded View 2 3 8 4 1 5...

Page 6: ...6 Figure 7 System Wiring 5 Wire Harness 6 Wire Harness 5 Wire Harness 5 Wire Harness 5 Wire Harness Yellow for MM MG furnaces Grey for M1 furnaces...

Page 7: ...7 Figure 8 Wiring Schematics 2 Wire Circuit Board used in relay box 903092A 2 Wire Circuit Board used in relay box 902898A...