C8BA Series Split System Uncased Indoor Coils - Brazed

INSTALLATION INSTRUCTIONS

DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

IMPORTANT

ATTENTION INSTALLERS:

It is your responsibility to know this product better than your customer. This includes being 
able to install the product according to strict safety guidelines and instructing the customer on 
how to operate and maintain the equipment for the life of the product. Safety should always be 
the deciding factor when installing this product and using common sense plays an important 
role as well. Pay attention to all safety warnings and any other special notes highlighted in the 
manual. Improper installation of the furnace or failure to follow safety warnings could result 
in serious injury, death, or property damage.

These instructions are primarily intended to assist qualified individuals experienced in the 
proper installation of this appliance. Some local codes require licensed installation/service 
personnel for this type of equipment. Please read all instructions carefully before starting the 
installation. Return these instructions to the customer’s package for future reference.

Summary of Contents for C8BA Series

Page 1: ...ing factor when installing this product and using common sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or property damage These instructions are primarily intended to assist qualified individuals experience...

Page 2: ...ation of this unit Unqualified individuals should not attempt to interpret these instructions or install this equipment If you do not posses mechanical skills or tools call your local dealer forassistance Undernocircumstancesshould the equipment owner attempt to install and or service this equipment Failure to follow safety recommendations could result in possible damage to the equipment serious p...

Page 3: ... could result in serious injury or property damage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectallelectricalpower to the furnace and outdoor condensing unit When servicing controls label all wires prior to disconnecting Reconnect wires correctly Verify proper operation after servicing CAUTION The coil must be level to ens...

Page 4: ... distributor body and hand tighten both components Mark a line on both bodies and then tighten an additional 1 4 turn using two wrenches The movement of the two lines will show how much the nut is tightened If a torque wrench is used tighten to 10 12 ft lbs or 14 16 Nm Connecting the Linesets 1 Route and cut both lineset tubes to proper length in accordance with the outdoor unit specifications Ver...

Page 5: ...a minimum horizontal slope in the direction of discharge of not less than 1 vertical for every 10 ft of horizontal run During system checkout inspect the drain line and connections to verify proper condensate drainage Maintenance Service WARNING ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Improper servicing c...

Page 6: ...ction Line in 3 4 3 4 7 8 Installed Orifice Size in 061 067 071 NOTES 1 Individual restrictors are available by part number PN664 where represents the size Example 664103 is a restrictor 0 103 in diameter 2 RefertosalesspecificationsheetsforListed Certifiedcombinationsofequipmentandrequiredaccessories 3 Refer to the current AHRI directory for certified ratings of split systems 4 Based on a nominal...

Page 7: ...7 ...

Page 8: ...ications illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U S A 02 12 709278A Replaces 7092780 INSTALLER PLEASE LEAVE THESE INSTRUCTIONS WITH THE EQUIPMENT OWNER ...

Reviews: