![NORDWEST PROMAT 4000851221 Original Instruction Manual Download Page 10](http://html1.mh-extra.com/html/nordwest/promat-4000851221/promat-4000851221_original-instruction-manual_1704592010.webp)
6
Operation
Troubleshooting
Problem
Possible Cause
Solution
No Display
Low Battery
Poor Contact
Replace Battery
Clean Contacts
Display frozen
Display shows Error
Message
Processor Crashed
Remove Battery and
reinsert after one Minute
Technical Data
Resolution: ..................................... 0.01 mm
Power supply: ................................. 1 silver oxide battery CR2032 (3 V)
Measuring speed: ........................... ≤1.5 m/s
Operating temperature ................... 0~+40° C
Relative humidity: ........................... <80%
Storage temperature: ...................... -10° C and +60° C
Automatic switch off function