OBSOLETE
21-37
Issued 7/96
3
Daily Operation
Delivery System Start-Up
1. Perform the necessary tasks to start-up the Iso-Flo
HD unit.
2. Check all fluid and air lines for leaks.
Setting Flow Rate
WARNING: Risk of electrical shock. Make
sure that the electrostatic power unit is turned
off and the fluid supply is properly grounded.
Failure to observe this warning may result in
personal injury, death, or equipment damage.
1. Turn off air supply.
2. Slide the trigger lock (14) all the way down.
3. Perform the tasks necessary to set fluid pressure
in the fluid delivery system. Use the lowest fluid
pressure possible to obtain a satisfactory flow rate
of your coating material.
4. Fully trigger the WM-1 spray gun into a graduated
container. Use a stop watch to establish the time
needed to collect the desired amount of fluid.
5. Repeat steps 3 and 4 until the desired flow rate
per minute is obtained.
Preparing to Spray
1. Turn on air supply.
2. Perform the tasks necessary to set the supply air
pressure to the WM-1 spray gun. Use the lowest
air pressure possible to obtain satisfactory
atomization of your coating material.
3. Fully trigger the WM-1 spray gun.
4. Turn the thumb wheel (7) to achieve your desired
spray pattern.
5. Repeat steps 2, 3, and 4 until the desired spray
pattern and atomization is obtained. If necessary,
adjust the Iso-Flo HD unit fluid and air pressure.
6. Cover the exterior of the WM-1 spray gun with a
Nordson spray gun cover.
7. Turn on the electrostatic power supply.
8. The system is now operational.