Parameters for ALL motors
Control panel
AND standard I/O
Field bus
Parameters for ALL motors
Control panel
Interface of line speed signal
XS5
Interface of line speed signal
Max. in key-to-line
mode
Analog
9.8
Parameters for ALL motors
Line speed
signal
Voltage
0‐20 mA
9.8
V
V
Act
ual
Fig. 4‐95
M2.1
Operation
4‐68
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Motor
(contd.)
Parameters (Screen 1: Type of Motor Enable,
Adaptation to Parent Machine)
: Motor Enable Via Control Panel / Control Panel AND Standard I/O
Control panel:
The
Standard I/O
interface signals
All motors ON/OFF
(collective enable)
and
Enable motor
are deactivated.
The motors can then only be enabled and switched on via the control panel.
In this case the melter can function even without a standard I/O connection to
the parent machine, e.g. if it is to be purged for maintenance purposes.
With the option
Field bus communication
, other enables may be required,
depending on the control mode selected (Fig. 4‐72 to 4‐79). Depending on
the control mode, the control panel may be deactivated (only parameter
display is possible).
Enable motor via
Control Panel
Interface for line speed
When a field bus‐based control mode (field bus, field bus (extended), dual
and dual (extended)) is used, the source of the line speed signal can be
either the field bus (Fig. 4 ‐‐94, bottom) or the interface
Key‐to‐line mode
Field Bus
Line Speed Signal
Either
Analog
or
Frequency
can be selected, and either
Voltage
or
current
can be selected for
Analog
. Depending on what is selected, the keys not
used will be transparent and the units will change.
0-20 mA
or
4-20 mA
is
retrieved from the I/O board.
NOTE:
Voltage or current and 0 - 20 mA or 4 - 20 mA must have been set on
the I/O board with the DIP switches (Refer to section
Installation
). The switch
setting is loaded once when the melter starts up, and it is displayed on the
control panel.
Max. in key-to-line mode
For calibration with the signal (voltage, current or frequency) received from
the parent machine.
Example of operation with pilot voltage: The parent machine runs at
maximum speed. An input signal of 9.8 V (
actual
value) is displayed. Then
set
Max. in key-to-line mode
to 9.8.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...