Nordson iDry
r
Series Induction Dryers
31
Part 1075452
−
04
E
2016 Nordson Corporation
Adjusting the Temperature Setpoint
NOTE:
The actual and setpoint temperature can be displayed in either
Celsisus or Fahrenheit. To change the display, refer to page 27. Refer to
page 50 for a chart showing Celsius to Fahrenheit conversions.
A typical temperature setpoint is 65
−
70
_
C (149
−
158
_
F). The temperature
setpoint can be password-protected so it cannot be changed by the
operator. Refer to page 28 for information on protecting the setpoint.
The temperature setpoint can be adjusted in two ways:
S
Touch the
Up
(
Y
) or
Down
(
B
) buttons to change the setpoint
temperature one degree at a time.
S
For larger adjustments, touch the setpoint temperature value (5). A
numerical keypad will appear. Set a new setpoint and touch the
ENT
button on the keypad to save the setting.
Manual Mode
The dryer can also be operated in Manual mode. The Manual mode screen
can be password protected so that it cannot be accessed. Access is turned
off by default. Refer to page 28 for information on accessing the Manual
mode screen.
This screen allows the dryer to operate in open loop mode, with no
temperature feedback. The % of power setpoint controls the dryer and
must be set to run the dryer in manual mode. If a thermocouple is installed
the actual can end temperature will be displayed, however the
thermocouple feedback is not required or used to operate the dryer in this
mode.
1
2
3
4
5
6
Figure 27 Manual Mode Screen
1. Actual temperature value
2. Actual temperature bar graph
3. Percent power bar graph
4. Power setpoint
5. Up and down buttons
6. Mode indicators