Nordson iDry
r
Series Induction Dryers
27
Part 1075452
−
04
E
2016 Nordson Corporation
Temperature Setpoint, Display, and Alarm Settings
Touch the
TEMP SETUP
button on the Navigation screen (Figure 16). The
Temperature Setpoint, Display, and Alarms screen appears. This screen
can be password-protected.
Figure 23 Temperature Setpoint, Display, and Alarm Screen
Product Temperature Setpoint
This setting duplicates the setpoint display on the Auto Mode screen. The
controller will attempt to maintain the temperature of the can ends exiting
the dryer at this setting.
Alarm Setpoints
If the product temperature increases to the
ALARM HIGH SETPOINT
or
decreases to the
ALARM LOW SETPOINT
an alarm fault is issued and the
dryer will shut down. The factory default setting for each is 20 degrees.
Touch the setpoint field and use the keypad to enter the desired setpoint.
Touch the
ENT
key to save your setting.
Temperature Alarm Delay
This is a timer that delays the activation of an temperature fault if the Alarm
High or Alarm Low setpoints are exceeded. The factory default settings is 5
seconds.
Touch the
TEMPERATURE ALARM DELAY
field and use the keypad to
enter the desired setpoint. Touch the
ENT
key to save your setting.
Temperature Display Selection
Touch the display field to toggle between
C
(Celsisus) or
F
(Fahrenheit).