Operational Faults (Red LED Flashing)
If either Empty or Full programming cannot be completed, the red LED flashes quickly.
Task
Procedure
Clearing a Fault
Clear the fault by either:
• pressing the programming button once, or
• cycling feed center power.
Correcting Faults
Check for and correct any of these possible causes for the fault:
•
The difference between Empty and Full is not great enough.
Reprogram the level sensor.
• Empty programming done while the probe was in the powder,
or Full programming done while the probe was out of the
powder.
• During Empty programming, the distance between the probe
and the powder was too short.
Two Button Level Sensor Probe Programming
When you program the level sensor probe, the powder feed center exhaust fan must be
on and the powder in the hopper must be thoroughly fluidized.
OUT OFF
Programming
Button
LED Ring
OUT ON
Programming
Button
Figure 4-3 Programming the Two Button Level Sensor Probe
LED Functions
LED Color
Status
Means
Green
On
Material not detected
Yellow
On
Material detected
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......