© 2021 Nordson Corporation
8-28
Vibratory Table Isolator Mount Replacement
1. See Figure 8-23. Remove the four socket-head cap screws (1) and lock washers (2)
securing the vibrator motor (3) to the vibratory table.
2. Carefully remove the vibrator motor and set it at the back of the feed center.
3. Unscrew and remove the nuts (5) and washers (6) from top of vibratory table (4).
4. Carefully lift the vibratory table out of the feed center and stand it up on its front edge.
5. Unscrew the hex screws (7) to remove the the four isolator mounts (8) from the
vibratory table.
6. Install new isolator mounts with hex screws onto the vibratory table and follow steps
1-4 in reverse to install the vibratory table into the feed center.
5
6
7
8
1
3
4
2
Figure 8-23 Vibratory Table Isolator Mount Replacement (Side View of Vibratory Table)
1. Screws
2. Lock washers
3. Vibrator motor
4. Vibratory table
5. Nuts
6. Washers
7. Hex screws
8. Isolator mounts