Operation
8-6
Part 1056418-07
E
2019 Nordson Corporation
Part ID Control
The
Part ID Control
button on the Main screen displays the current part ID
mode. Touching the button opens the Part ID Control screen.
Auto
Manual
Part ID
Select
Enter
Global Control Screen
−
Manual Preset and Trigger Control
Part ID Modes
Auto:
The part ID is entered into the part queue by signals received from
the flag photoeyes or a customer part ID system. Parts are sprayed
automatically.
Manual:
The part ID is selected and entered by the operator. Typically
used for batch coating.
NOTE:
Manually changing the part ID affects only the part entering the
booth, not the part currently being sprayed.
Batch Coating
1. Select
Manual
mode.
2. Select a part ID number.
3. Touch the
Enter
button to enter the new part ID into the part queue.
NOTE:
If you enter a new part ID number while a part is passing in front of
the zone photoeyes, the part will be sprayed first by the preset for the
previous part ID number, then by the preset for the new part ID number.
NOTE:
If the part ID inputs are configured for Straight Flagging and you
want to spray a part with a preset number greater than 8, you must do it
manually using Global Manual Triggering (page 8-5). Straight flagging
only allows Part IDs from 1
−
8. Any preset number greater than 8 will be
forced to 8.
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...