Scanner Cable Connections
See Figure 3-8. The PEJB and scanner junction boxes are shipped with the scanner
cables pre-wired to the junction boxes. The scanner controllers are programmed at the
factory according to the system order specifications.
Refer to the system plan views when locating the part ID stand and scanners or
photoeyes. The scanners must be mounted with the cable ends oriented as shown.
Discrete Scanner Connections
• Single-Zone Scanner: SCNR1 cables to scanner.
• Dual-Zone Scanners: SCNR1 cables to upper scanner, SCNR2 cables to lower
scanner.
• Part ID Scanner and Zone Scanner: SCNR1 cables to zone scanner, SCNR2 cables to
part ID scanner.
NOTE:
The part ID scanner or photoeyes must be located so that the iControl 2 system
receives the part ID before the leading edge of the part breaks the zone scanners or
photoeyes.
PEJB
PD1
PEJB
PD1
SCNR1
SCNR2
PEJB
PD1
SCNR1
Single-Zone Scanner
Dual-Zone Scanner
Part ID Scanner
Zone Scanner
Part Travel
Part ID and Zone Scanners
Figure 3-8 Zone and Part ID Scanner Cable Connections (Typical)
Summary of Contents for Encore HD iControl 2
Page 6: ...2022 Nordson Corporation 1609758 04 iv Table of Contents...
Page 8: ...2022 Nordson Corporation 1609758 04 ii Change Record...
Page 84: ...2022 Nordson Corporation 1609758 04 4 34 Troubleshooting...
Page 102: ...2022 Nordson Corporation 1609758 04 6 12 Parts...
Page 104: ...2022 Nordson Corporation 1609758 04 7 2 Drawings...
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 113: ......
Page 114: ......