© 2022 Nordson Corporation
3-10
Power Connections
The console power cable plugs into the AC IN receptacle on the rear of the console. The
cable is routed to the system electrical panel and connected to a terminal block.
CAUTION:
The 120-watt 24 Vdc power supply mounted on the DIN rail at the bottom of
the console is not autosensing. It is set at the factory for 230V. If supplying 110V to the
iControl 2 console, the power supply must be switched to 110V. If switching from 110V to
230V in the future, the power supply MUST be switched to 230V before connecting
power to the console.
Table 3-2 lists the connections required for both main and auxiliary consoles.
Console Power Cable Connections
Table 3-2 Console Power Cable Connections
Main Console Power Cable Connections
Wire Color
Pin
Function
Whit/Blk
1
Conveyor run AC common
Black
2
Non-interlocked AC
White
3
Non-interlocked AC common
Red
4
Interlocked AC
Orange
5
Conveyor run AC
Blue
6
Interlocked AC common
Green
7
Ground
Auxiliary Console Power Cable Connections
Wire Color
Pin
Connection
Black
2
Interlocked AC (same as main console Red connection)
White
3
Interlocked AC common (same as main console Blue connection)
Green
1
GND
Summary of Contents for Encore HD iControl 2
Page 6: ...2022 Nordson Corporation 1609758 04 iv Table of Contents...
Page 8: ...2022 Nordson Corporation 1609758 04 ii Change Record...
Page 84: ...2022 Nordson Corporation 1609758 04 4 34 Troubleshooting...
Page 102: ...2022 Nordson Corporation 1609758 04 6 12 Parts...
Page 104: ...2022 Nordson Corporation 1609758 04 7 2 Drawings...
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 113: ......
Page 114: ......