Green Tip Settings
Test
Pressure
Time
Dot Size
A
30 psi
B
20 psi
C
20 psi
D
15 psi
Dot Tests
Dot Test with Green Tapered Tip
First, follow the settings illustrated on the left, and you will get dots
about the size shown. Try other times and pressures to see how
easy it is to get just the dot size you want.
Dot Test with Blue Tapered Tip
These tests show the effect of using a smaller diameter tip.
Replace the green tip with the blue tapered tip. Now, press the timer
bypass button (dashes appear) and press the foot pedal to fill
the tip. Then, press the bypass button to restore time last used
(0.10). Press the bottom right button to change from a 0 to a 5.
Time displayed now shows 0.15
.
(For Test G, change the time back
to 0.10)
.
Programming Deposit Size
Press the program button (top left). This zeros out the display
and you will see 000
(Fig. 1).
The decimal will not show. Note that
the display flashes bright/dim. This flashing indicates you are in the
program mode.
Position the tip on the largest test circle. Press the foot pedal and
when the test fluid fills the circle, release the foot pedal. Note the
time on the flashing display. Press the program button once.
The time remains and the flashing stops.
Position the tip and momentarily press the foot pedal. The displayed
time zeros and counts up to and stops at the programmed time. This
time will be repeated each time the foot pedal is pressed.
To change dispensing time, either enter the program mode to zero
out the display, or change the displayed digits by pressing the
buttons below them.
- Use the convenient Dot Test sheet included.
21
(Fig. 1)
Blue Tip Settings
Test
Pressure
Time
Dot Size
E
30 psi
F
20 psi
G
20 psi
0
2
5
.
0
2
5
.
0
1
0
.
0
1
0
.
0
1
5
.
0
1
5
.
0
1
0
.
0
0
0