4-14
Power-Up
and
Testing
4.10.4 Light Beacon
Perform the following procedures to check function of the Light Beacon.
To test the Light Beacon:
1.
Close the dispensing system hood, make sure the EMO is deactivated, and press the green
ON
(
l
)
button on the front panel.
!
The green beacon light should be ON.
2.
Open the hood.
!
The yellow beacon light should come ON and the green beacon light should go OFF.
3.
Close the dispensing system hood.
!
The green beacon light should come ON and the yellow beacon light should go OFF.
4.
In the FmXP Main Window, click on
Tools
.
5.
In the Tools Window, click on
I/O Test
.
6.
Click on
Dispenser
.
!
The I/O Test Dialog screen opens.
7.
Locate the tab (Figure 4-10) with the beacon color outputs (
BEACON_YELLOW
, etc.).
8.
Make sure the
SOFTWARE_ACTIVE
bit is
ON
(
l
). If not, the beacon lights will not toggle.
Figure 4-10 Dispenser I/O (Outputs 32-63)
9.
Toggle the button next to the desired output
ON
(
l
) and
OFF
(
0
) to test the beacon signal.
10.
Click on
OK
to return to the Tools Window.
11.
Click on
Main
to return to the Main Window.
Summary of Contents for Asymtek Spectrum S-920
Page 2: ......
Page 4: ......
Page 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Page 124: ......
Page 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Page 190: ......
Page 204: ......
Page 208: ......
Page 210: ......
Page 220: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 234: ......