Calibration and Adjustment
5-9
5.9 Z-head Counterbalance Force Adjustment
The Z-head Counterbalance Force prevents the Z-head from crashing down upon disengagement of the
motor. There are three settings to accommodate various payloads.
To adjust the Z-head counterbalance (Figure 5-11):
1.
Using a 3 mm hex key, loosen the screw on the lower Z-spring.
2.
Move screw down to increase tension.
!
If necessary, move screw up to decrease tension.
To test counterbalance tension:
1.
Place valve on Z-head.
2.
Move Z-head to middle of dispense area.
3.
Open machine hood.
!
Z-head should not drop more the 25.4 mm (1-inch).
4.
Readjust tension if necessary.