Nordson 7440272 Quick Start Manual Download Page 4

Pro-Meter V2K

 

 

 

3.  Connect discharge port hoses to each metering cartridge assembly discharge port. Refer to the 

Pro-Meter 

V2K Fittings Kit Instruction Sheet

 (Nordson part number 7441865) for additional information. 

 

 

 

4.  Mount dispense valve  assembly  to dispense valve support fixture (if equipped) and connect  air and 

material lines. 

 

 

 

5.  Install the mixer to the dispense valve. To support initial startup and testing, each Pro−Meter V2K system 

is supplied with a Mixer Variety Kit. Refer to the 

Pro-Meter V2K Mixer Variety Kit Instruction Sheet

  

(Nordson part number 7441857) for additional information. To support ongoing operations and to provide 

optimum dispense flexibility, a Mixer Startup Kit can be ordered. Refer to 

Pro-Meter V2K Mixer Selection 

Guide Instruction Sheet

 (Nordson part number 7441862) for additional information.  

6.  Ensure the gravity tank gaskets are compatible with the selected material.  

7. 

CAUTION: 

 

  Ensure the gravity tank gasket is seated evenly at the bottom of the cam-lock. 

  Confirm gasket compatibility with TDS and SDS or material supplier.   

NOTE:  

  The gravity tanks come equipped with nitrile (Buna-N

®

) gaskets. 

  Each Pro-Meter V2K is shipped with a gravity tank gasket kit (Nordson part number 7440614). The 

kit contains 2 EPDM gaskets (Nordson

 part number 7440611), 2 silicone gaskets (Nordson part

number 7440613), and 2 Viton

® 

gaskets 

(Nordson part number 7440612). 

  If the gravity tank gaskets are not compatible with the selected material, loosen the cam-lock fittings 

located between the manual ball valve and actuated valve below the tanks and utilize a seal puller, or 

equivalent tool, to remove the gravity tank gaskets. Carefully install the correct gravity tank gasket by 

hand into the cam-lock. 

 

 

 

 

 

 

 

 

 

 

4

Summary of Contents for 7440272

Page 1: ...application Dispense valve assembly Fitting kit TOOLS REQUIRED FOR INSTALLATION Ratcheting wrenches Adjustable wrenches Box cutter to cut crate tie straps Hammer to open crate Metric hex keys Metric s...

Page 2: ...RNING Any material injected into flesh can cause severe injury or death Keep body parts awayfrom material discharge ports If injection occurs seek medical attention immediately WARNING Operating fault...

Page 3: ...blue and P6 red female connectors located at the power supply Refer to the System Layout Drawing for additional information NOTE The HMI pendant harness connectors are labeled P5 and P6 and are unique...

Page 4: ...ruction Sheet Nordson part number 7441862 for additional information 6 Ensure the gravity tank gaskets are compatible with the selected material 7 CAUTION Ensure the gravity tank gasket is seated even...

Page 5: ...power switch located at the power supply to the ON position NOTE Refer to the Pro Meter V2K Screen Map in Appendix A for additional information 1 Proceed to Main Menu Screen 2 Select SETUP LOGIN pushb...

Page 6: ...shbuttons Cylinder Setup 1 From the Main Menu Screen select the SETUP LOGIN pushbutton and proceed to the Setup Login Screen 2 From the Setup Login Screen select the LEVEL 1 SETUP pushbutton to procee...

Page 7: ...ly close the air cylinder flow controls Slowly open the flow controls at turn intervals until the desired flow rate is achieved 3 From the Main Menu Screen proceed to the Setup Login Screen to the Lev...

Page 8: ...he air cylinder is allowed to fully return as the RETURN RODS pushbutton is depressed 6 With the air cylinder fully extended verify the existence of a small gap between the stop block and the carriage...

Page 9: ...READING data display into the FULL SCALE MM CAL VALVE data entry field NOTE The linear position sensor should now be calibrated 10 With the rods fully returned utilize a 6 mm wrench or equivalent too...

Page 10: ...ure Sensor Calibration Screen 11 Enter the 0 psi Cal value and the Full Scale psi value 250 psi from the calibration sheet 12 Adjust the Zero Offset until the Scaled Pressure reads zero CAUTION If the...

Page 11: ...cle will be run The purge timer will then reset Manual Shot Mode When the dispense command is given either by the foot switch or the DISPENSE pushbutton on the Dispense 1 Screen the Pro Meter V2K will...

Page 12: ...our local Nordson Sealant Equipment Representative to order the purge cord Option 2 The customer purchases a jumper kit Nordson part number 7442948 and manually installs a jumper to pins 3 and 4 of th...

Page 13: ...or fault The Pro Meter V2K will remain operational unless some other fault interferes with operation When the PURGE TIMER is turned ON the TIME LEFT TO PURGE will be displayed While in Manual Mode the...

Page 14: ...supply line customer supplied 4 7440843 Purge ok splitter if supplied 5 7440844 Machine interlock cordset if supplied 6 7440845 Footswitch if supplied OR 7442945 Hand trigger if supplied 7 7442948 Pur...

Page 15: ...close to 75cc as possible Stroke Setup 2 From the Level 1 Setup Screen proceed to the Valve Setup Screen 3 Depress the ADVANCE RODS pushbutton until the air cylinder is fully retracted Stroke Length S...

Page 16: ...ch or equivalent tool and move the stop block until the gap is as close to 4 14 inch 10 52 cm NOTE It may be necessary to make further adjustments to fine tune the dispense volume It is also possible...

Page 17: ...on Select the Return Rods pushbutton to place the carriage in the METER FULL POSITION 3 Position the ball valves located just below the gravity tanks to the OPEN position NOTE When the ball valves are...

Page 18: ...nd Volume Adjustment Linear Speed Control Calibration 1 Utilize a 1 8 inch or 3 mm hex key adjust the air cylinder flow control valve in the open position WARNING Slowly adjust the flow control valve...

Page 19: ...gently pry open low level sensor adjustment screw access cover B 2 Turn low level sensor adjustment screw A slowly counter clockwise with a small flat head screwdriver until the sensor turns ON 3 Tur...

Page 20: ...APPENDIX A 20...

Page 21: ...Issued 7 2018 Original copyright date 2017 Pro Meter and the Nordson logo are registered trademarks of Nordson Corporation www nordson com nse 1 800 433 9319 21...

Reviews: