3
Installation Instructions for Series 3100V Level Switch
E
2000 Nordson Corporation
All rights reserved
321 355A
Issued 5/00
41--3000--IS--65
4131091A
Fig. 2 Low-level Switch Connected to Pump Pan
Follow this procedure to prepare for installation.
WARNING:
Hot! Risk of burns. Wear heat-protective clothing,
safety goggles, and heat-protective gloves. Hot melt material
may be released forcefully.
1. Drain all adhesive from the tank and disconnect main air supply.
WARNING:
The melter contains energized electrical
components with potentials that could be fatal. Disconnect and
lock out input electrical power to the melter before proceeding
further.
2. Remove the pump cover.
3. Remove the electrical enclosure lid and the front and rear covers.
4. Remove the screws holding the pump pan to the tank cover.
5. Clean the tank of all debris; then remove the pump, pan, tank cover,
and gaskets.
Preparing for Installation