Low Level Sensor (If Equipped)
Removal
WARNING:
Relieve system air pressure, material pressure, and disconnect power
prior to servicing Pro
−
Meter V2K components. Refer to
Preparation For Maintenance And Service (page 8
information.
Allow only qualified personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
Clean any material that has spilled. Be sure to follow all applicable
safety and environmental guidelines when cleaning spilled material.
Refer to
1. Disconnect electrical harness connector from low level sensor.
CAUTION:
Do not kink or otherwise damage electrical harness connector.
2. Remove low level sensor from low level sensor bracket located on
gravity tank.
CAUTION:
Do not attempt to remove the low level sensor bracket from the
gravity tank.
Installation
Installation of the low level sensor is in the reverse order of removal.
CAUTION:
Do not kink or otherwise damage electrical harness connector.
Calibrate the low level sensor. Refer to
Low Level Sensor Calibration (page 6
for low level sensor calibration
procedure.