System Setup and Calibration
6-9
Part 7440274
2017 Nordson Corporation
Low Level Sensor Calibration
NOTE:
Low level sensors are equipped on Pro
−
Meter V2K systems with gravity
tanks.
This capacitive sensor requires calibration in accordance with the
medium utilized.
CAUTION:
Ensure dispense material added to the gravity tanks is at least
1 inch (25.4 mm) higher than the low level sensors.
1. Utilize a small flat head screw driver to gently pry open low level sensor
adjustment screw access cover (B).
2. Turn low level sensor adjustment screw (A) slowly counter
−
clockwise
with a small flat
−
head screwdriver until the sensor turns ON.
3. Turn low level sensor adjustment screw (A) slowly clockwise with a
small flat
−
head screwdriver until the sensor turns OFF.
4. From the position where the sensor turns OFF, turn the low level sensor
adjustment screw (A) an additional half rotation (180
) clockwise with a
small flat
−
head screwdriver
.
A
B
Figure 6-8
Low Level Sensor Calibration