System Setup and Calibration
6-6
Part 7440274
2017 Nordson Corporation
Adjustment And Calibration
HMI Pendant Login
1. Proceed to
Main Menu
HMI Pendant Screen.
2. Select
SETUP LOGIN
push button to proceed to Setup Login HMI
Pendant Screen.
3. Log into the HMI Pendant using the default user name and password.
The default user name is ‘2’. The default password is also ‘2’.
NOTE:
Proceed to
Main Menu
HMI Pendant Screen.
Select
Setup Login
push button
to proceed to
Setup Login
HMI Pendant
Screen.
Select
Level 2 Setup
to proceed to
Level 2 Setup
HMI Pendant Screen.
Select
RESET PASSWORD
to proceed to
Reset Password
HMI
Pendant Screen.
Select
Reset Password
push button and follow prompts.
Air Actuator Flow Adjustment
Dispense and reload speed may be adjusted by adjusting the flow control
valves located on the air actuator. The flow control valve positioned closest
to the carriage is utilized to adjust the reload speed. The flow control valve
positioned closest to the gravity tank bracket is utilized to control the
dispense speed. Utilize a hex key to make fine adjustments to the
respective flow control valves until the desired dispense/reload speeds are
achieved.