Typical Setup
All EFD valves are supplied with an installation manual. The manual will explain the operation of the valve
and also how to set up the valve with the fluid reservoir.
Always depressurize the reservoir before opening. To do this, slide the shutoff valve on the air line
away from the reservoir. If using an EFD tank, open the pressure relief valve as well. Before opening the
reservoir, check the pressure gauge to verify that the pressure is zero (0).
On all EFD cartridge reservoirs, the unique threaded design provides fail-safe air pressure release during
cap removal.
CAUTION
5-micron filter /
regulator
Air tee
To exhaust
To pressurize
Plant air
4.8 bar
(70 psi )
White quick-connect
Black quick-
connect
Pressure
relief valve
EFD
dispense
valve
Pressurized reservoir
with air regulator
ValveMate 7100
Controller
Flexible air line
Shut-off valve
Material
Constant air
NOTE:
Use only oil-free,
clean, dry filtered air.
Actuating air