Valve maintenance

To thoroughly clean the fluid body and
replace needle packings:

1. Remove needle stroke control knob

and spring.

2. Remove the gear cover.

3. Remove the rotor retainer nut, then

the rotor, nozzle, fittings and motor
from the fluid body.

4. Remove the motor mount and

motor assembly.

5. Remove the fluid body from the air

cylinder body. Remove the O-ring
from the fluid body.

6. Clean the fluid body, rotor and noz-

zle in appropriate solvent.

Note:

Rotor bearings can be soaked in

light oil for one hour to penetrate past
the seals. Replace bearings if rotor does
not rotate smoothly.

7. Use tool #7803 to remove needle

packings from fluid body.

8. Remove any remaining packings

and the spring from the needle.

Note:

The lower cylinder needle O-ring

is held in place by a flat retaining washer
that also serves as the packing-spring
seat. The washer may come out with
the spring. Ensure that it is back in place
before reinstalling the packing spring.

9. Clean the needle with a cloth

dampened in solvent.

Valve Disassembly 
and Reassembly Procedures