Replacing the Battery
Follow these steps to replace the battery:
1. Remove the flat-head screws to extract the PICO controller from the electrical cabinet;
detach cables.
2. Release the four M3 outer hexagon screws from the front panel.
3. Carefully pull the front plate out approximately 5 cm by the handle, taking care not to
pull or stretch the internal cables.
4. Place the PICO controller on its side such that the circuit board with the battery is on
the bottom.
NOTE:
If needed for space, the plug connection between the front and the side (lower)
circuit board can be removed.
5. Use a suitable tool (e.g., a screwdriver) to extract the battery from under the bracket.
6. Insert a new battery.
7. Reassemble the unit in reverse order.
Replacement Parts
Part #
Description
7027455
Cable, power, 24V, 2.0 m (PICO controller power supply cable)
7028222
Cable, PICO controller /
Toµch
controller / PLC, 1. 0+ 2.0 m (Y-cable)
NOTE:
This cable is ordered separately.
Part Numbers
Part #
Description
7015899
PICO Controller 2+2-XCH-V2, 2 channel
7015900
PICO Controller 2+2-XCH-V2, 4 channel
PICO Controller 2+2-XCH-V2
45
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.