1. Prior to assembling the insert
All our products are tested according to the latest
European requirements and also
to the Norwegian
standard NS 3058 and NS 3059,
which include
particle tests. However, several European countries
have local regulations for installation of fireplaces,
which change regularly. It is the responsibility
of the client that these regulations are complied
with in the country/region where the fireplace is
installed. Nordpeis AS is not responsible for incorrect
installation.
Important to check
(please note that this list is not exhaustive):
•
distance from firebox to combustible/flammable
materials
•
insulation materials/requirements between
fireplace surround and back wall
•
size of floor plates in front of fireplace if required
•
flue connection between firebox and chimney
•
insulation requirements if flue passes through a
flammable wall
Chimney draught
Compared with older models, the clean burning
inserts of today put significantly higher demands
on the chimney. Even the best insert will not work
properly if the chimney does not have the right
dimensions or is not in good working order. The
draught is mainly controlled by gas temperature,
outside temperature, air supply as well as the height
and inner diameter of the chimney. The diameter of
the chimney should never be less than that of the flue/
chimney collar. At nominal effect there should be a
negative pressure of 12 to 25 Pascal.
The draught increases when:
•
The chimney becomes warmer than the outside air
•
The active length of the chimney over the hearth
increases
•
There is good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the insert,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper.
Air supply
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems,
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared
for direct supply of outside air. In older houses, the
use of fresh air supply set is also recommended.
Insufficient air supply can cause down-draught and
thereby low combustion efficiency and the problems
that this entails: soot stains on the glass, inefficient
1. Prior to assembling the insert
10
Chimney Draught
10
Air Supply
10
2. Technical Information
11
3. Distance to combustible material
11
4. Assembly
11
Connection of the flue
12
Operational control
12
Painting the surround
12
5. Lighting the fire for the first time
12
6. Maintenance
13
Cleaning and inspection
13
Ashes
13
Thermotte™
13
Door and glass
13
7. Warranty
14
8. Advice on lighting a fire
14
Some advice in case of combustion problems 15
INDEX
Summary of Contents for N-24 round
Page 9: ...9 NO Produktdokumentasjon...
Page 35: ...35 N 24 mm 118 284 538 3 6 512 548 310 695 970 853 330 210 510 136 148 35...
Page 39: ...39 FIG 6 FIG 9A X4 A B 1 2 FIG 9B 9 5 8 7 6 3 1 4 2 FIG 8 7 FIG 7A FIG 7B...
Page 40: ...FIG 10 1 2 3 4 Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...