NO Monterings- og bruksanvisning
2
GB Installation- and user manual
9
Glasgow
Product no:
SN-GLASG-010
Test report no: RRF: 40 16 4328
Last updated: 16.08.2016
Page 1: ...NO Monterings og bruksanvisning 2 GB Installation and user manual 9 Glasgow Product no SN GLASG 010 Test report no RRF 40 16 4328 Last updated 16 08 2016...
Page 2: ...ingen Er skorsteinen overdimensjonert i forhold til ildstedet kan det bli vanskelig oppn god trekk fordi skorsteinen ikke blir godt nok oppvarmet I slike tilfeller kan det l nne seg ta kontakt med kyn...
Page 3: ...Vekt 110 kg Temperatur r ykgass 239 C Luftbehov m h 11 Nom str innlegg time 1 1kg Ileggsintervall 47 min Luftventil pning 33 Driftsform Intermitterende Med intermitterende forbrenning menes her vanlig...
Page 4: ...eler er t rr klut godt egnet til b rste av med Montering av r ykr r Ved montering av r ykr r gj r vi oppmerksom p at 155 mm r ykr r skal inn i r ykstussen Benytt ovnskitt i skj tene For r ykinnf ring...
Page 5: ...mye aske og trykksverten er ikke bra for milj et Reklamer magasiner melkekartonger og lignende er ikke egnet for opptenning i peis Det er viktig med god lufttilf rsel ved opptenning N r skorsteinen b...
Page 6: ...metaller som er skadelige for milj et deg og ildstedet Saltsyren kan ogs angripe st let i skorsteinen eller murverket i en murt skorstein Unng ogs fyre med bark sagspon eller annet ekstremt fint kl yv...
Page 7: ...g ny pipe med st rre tverrsnitt Evt montering av r yksuger For lav pipe som gir d rlig trekk k pipeh yden og eller monter pipehatt r yksuger Ildstedet ryker inne n r det er vind ute Pipen ligger for l...
Page 8: ...det feiemuligheter for ildsted og r ykr r Er ildstedet sikret nok tilf rsel av forbrenningsluft via lufteventiler Er r ykr ret montert i skorstenen etter skorstensprodusentens anvisninger Er skorsten...
Page 9: ...fect there should be a negative pressure of 12 to 25 Pascal The draught increases when The chimney becomes warmer than the outside air The active length of the chimney over the hearth increases Good a...
Page 10: ...od logs 40 cm Operating range 5 kW nominal Efficiency 84 8 CO 13 O2 0 10 Draught system Air vent control Combustion system Secondary combustion clean burning Flue outlet Top and rear Flue Inner 155 mm...
Page 11: ...or leave the door slightly open each time new logs are Warning In order to avoid injuries please be aware that the surfaface may become hot during operation and that extra care need to be taken to avo...
Page 12: ...y glass Packaging Recycle The packaging accompanying the product should be recycled according to national regulations 7 Warranty For detailed description of the warranty conditions see the enclosed wa...
Page 13: ...ood is the higher the energy value Beech oak and birch has the highest density Attention We do not recommend using fuel briquettes compact wood in our products Use of such fuel may cause the product t...
Page 14: ...o a smaller fireplace or build new chimney with a larger cross section Possibly install a smoke suction device The chimney is too low and hence a poor draught Increase the height of the chimney and or...
Page 15: ...e Name Revision by Checked by Created by Approved by K sy Glasgow stove mm and air Glasgow M Sobkowski Nordpeis AS Gjellebekkstubben 11 N 3420 LIIERSKOGEN Norwey Glasgow air PE 127 272 5 545 155 170 3...
Page 16: ...00 300 Brannmur Brandmur Palomuuri Firewall Mur parefeu Hitzenschutzwand Brennbart materiale Br ndbart materiale Br nnbart material Tulenarka materiaali Combustible material Mati res combustibles Bren...
Page 17: ...17 FIG 3 FIG 2 FIG 4 FIG 5...
Page 18: ...18 FIG 6 FIG 7 FIG 8 FIG 9...
Page 19: ...de Hinten Seitlich 200mm 400 mm Emission of combustion Emissionswerte CO 0 10 vol NOx 100 mg m 3 OGC 95 mg m 3 PM Surface temperature Oberfl chentemperatur Pass Bestanden Machanical resistance Mechani...
Page 20: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...