L
N
3. INSTALLATION AND PREPARATIONS FOR USE
12
Figure 5
•
•
.
3.4 Gas conversion
:
Changing injectors:
•
.
•
•
•
The supply cord should be kept away from hot parts of appliance. Otherwise, the cord may be
damaged, causing short circuit.
The manufacturer declares that it has no responsibility against any kind of damages and losses
that are caused by improper connections that are performed by unauthorized people
Caution: The following procedures must be undertaken by authorized service people.
Your appliance is adjusted to be operated with LPG/NG gas. The gas burners can be adapted to
different types of gas, by replacing the corresponding injectors and adjusting minimum flame length
suitable to the gas in use. For this purpose, following steps should be performed
Cut off the main gas supply and unplug from the electric mains
Remove the burner cap and the adapter(Figure 6).
Unscrew the injectors. For this, use a 7mm spanner(Figure 7).
Replace the injector with the ones from the gas conversion kit, with corresponding diameters
suitable to the type of gas that is going to be used, according to the information chart (which is
also supplied in the gas conversion kit).
YELL
OW+GREEN
BL
U
E
BROW
N
3.3. Electric connection and safety
.
•
.
•
.
•
.
•
•
.
•
.
•
.
During the electric connection, follow the instructions stated in the user manual
The earthing cable must be connected to the earth terminal
You have to ensure the power cord with suitable insulation to be connected to the power source
during the connection If there is no appropriate earthed electric outlet in accordance with
regulations in the place where the appliance to be installed, contact to our authorized service.
The earthed electric outlet must be close to the appliance.
Do not use an extension cord
The power cord must not touch to the hot surface of the
product.
In case the cord is damaged, contact Authorized Service to
have it changed
Any wrong electric connection may damage your appliance,
as well as endangering your safety, rendering your guarantee
invalid
The appliance is adjusted for 230V 50Hz electricity. If the
mains electricity is different contact your authorized service