16
3.3. LED - DISPLAY ICONS
!
It indicates the
presence of an alarm
:
•
On: indicates the presence of an alarm
•
Off: indicates no alarms
Room Probe:
NOT USED
It indicates the
“SLEEP" function
(delayed switch-off)
•
Switched-off = SLEEP feature disabled
•
Switched-on = SLEEP feature activated
It indicates the
contact of the feeler
:
•
Switched-off = closed contact
•
Switched-on = open contact
It indicates the receipt of the radio signal:
NOT USED
It indicates
briquettes fed
:
•
Switched-off = motor disabled
•
Switched.on = motor activated
Indicates the
slide ascent motor
:
•
Switched-off = motor deactivated
•
Switched.on = motor activated
It indicates the
slide lowering motor
:
•
Switched-off = motor disabled
•
Switched.on = motor activated
Lowering limit switch
:
•
Switched-off = closed contact
•
Switched-on = open contact
It indicates the
stand-by input status
(GND/I2):
•
Off: contact open (satisfied)
•
On: closed contact (to be satisfied)
It indicates the status of the tank probe:
NOT USED
Lifting limit switch
:
•
Switched-off = closed contact
•
Switched-on = open contact
It indicates
stove operation
:
•
Switched-on = The stove is working in automatic mode
•
Switched-off = The stove is working in manual mode
•
Flashing = It switched to manual mode during a feeding cycle (cycle must be completed before switching to
manual mode)
It indicates
motor reset phase
:
•
Switched-off = reset not activated
•
Switched-on = reset activated
F1
Briquette feed limit switch
:
•
Switched-off = closed contact
•
Switched-on = open contact