You should have:
• 1 Radiator
• 4 Bracket Closing Caps
• 4 Bracket Hooks
• 4 Bracket Back Plates
• 4 Bracket Screws
You will need:
• Tape measure
• Electric drill and bits
• Spirit level
• Airvent key
• Appropriate wall fixings
• Spanner for valves and
vents
2. Contents
Technical Specifications
Materials
Aluminium
Connections
½" flow and return.
Test pressure
9 Bar
Testing authority
EN442
Maximum operating pressure
6 Bar
Maximum working temperature
90 ºC
Packaging
Polystyrene protection in cardboard box
All products must be inspected once removed
from the packaging and your point of
purchase notified within 28 days of delivery
of any scratches, blemishes or other
damage. Your point of purchase will then
agree appropriate action.
Imperfect radiators should therefore not be
fitted and we will not accept responsibility
for replacement of scratched or damaged
radiators once they have been fitted. This
includes any consequential loss or cost of
fitting.
If we are not notified within 28 days of the
date on the signed delivery note then it will be
deemed that we have fully complied with our
obligations and claims will not be considered.
Failure to comply with any of the above may
invalidate any claims. We recommend that
after you check the product on delivery that it is
stored in its packaging to prevent damage prior
to installation, we cannot accept responsibility
for items damaged after delivery.
Terms & Conditions
This product is guaranteed for 5 years. As we are not the manufacturers of this
product we will take all reasonable endeavours to make over to you the benefit of any
warranty or guarantee given by the manufacturer.
The guarantees in all cases are subject to the products being installed in accordance
with British and or European standards as well as these fitting instructions. The
guarantees in all cases are restricted to the free of charge replacement or repair
of the failed product only. Our liability will under no circumstances extend beyond
the repair or replacement of the product supplied by us. Claims for either labour in
replacement or damage to property are not admissible. Any goods that are returned,
in the event of a problem, will belong to us.
Guarantees & Liabilities
Refer to diagrams overleaf when installing
1. Accurately mark bracket holes on the wall using a tape
measure and spirit level. The bracket centres are positioned
153mm down from the top collector, and 103mm from either
side.
(Height of the radiator from floor : minimum 100mm)
2. Using suitable drill bits and plugs, insert suitable wall plugs. To
hang the top two brackets, secure the backplate ‘A’ with screws
‘B’ (or other suitable screws) going through into the wall plugs.
3. Insert the bracktets ‘C’ down into the back plate ‘A’ and secure
with the provided screw ‘D’. Then fit the closing cap ‘E’ on top.
4. Hang the radiator on the
second space
5. With the brackets in the correct position, take
down the radiator and fit the bottom two brackets by
repeating steps 1 to 4.
3. Installing radiator
Please Note: In accordance with Part L1 2006 of the
Building Regulations and BS7593:1992 code of practice for
the treatment of hot water and central heating systems,
we strongly recommend flushing the heating system post
installation of new radiators and then adding the correct
quantity and type of inhibitor for use with your radiator and
system to prevent corrosion. Damage caused to systems
not protected by a suitable inhibitor will not be covered by
manufacturer’s guarantee.
5. Commission Radiator
E
D
C
A
PLEASE NOTE:
To reduce the possibility of noise caused by rapid heating and cooling
of aluminium radiators; adequate capacity for expansion must be provided within
the overall heating system. Systems using micro bore pipework must have adequate
pressure and flow rates for the number and style of radiators on the system.
The diverter is marked with a
yellow cap and is fitted on the
radiator. The diverter can be
removed and swapped to the
other side if required.
However, we will not be
liable for any damages to the
radiator or paint finish as a
result of moving the diverter.
Diverter
Blanking Plug
4. Identifying the diverter
To Move the Diverter:
The diverter is situated behind the
blanking plug on the rear of the bottom collector. (on side marked
with yellow plug) Remove both the blanking plugs. Lift out the
cylindrical diverter and place it directly into the opposite collector
sleeve. Replace blanking plugs. (Please see diagram above).
ALUMINIUM_DESIGNER