Nordic Aluminium Designer Fitting Instructions Download Page 2

You should have: 

•  1 Radiator

•  4 Bracket Closing Caps

•  4 Bracket Hooks

•  4 Bracket Back Plates

•  4 Bracket Screws

You will need: 

•  Tape measure

•  Electric drill and bits

•  Spirit level 

•  Airvent key

•  Appropriate wall fixings

•  Spanner for valves and  

     vents

2. Contents

Technical Specifications

Materials

 

  

Aluminium

Connections

     

   

½" flow and return.

Test pressure

 

                         9 Bar

Testing authority

 

  

EN442

Maximum operating pressure

 

6 Bar

Maximum working temperature 

90 ºC 

Packaging

 

   

Polystyrene protection in cardboard box

All products must be inspected once removed 
from the packaging and your point of 
purchase notified within 28 days of delivery 
of any scratches, blemishes or other 
damage. Your point of purchase will then 
agree appropriate action.

Imperfect radiators should therefore not be 
fitted and we will not accept responsibility 
for replacement of scratched or damaged 
radiators once they have been fitted. This 
includes any consequential loss or cost of 
fitting. 

If we are not notified within 28 days of the 
date on the signed delivery note then it will be 
deemed that we have fully complied with our 
obligations and claims will not be considered. 

Failure to comply with any of the above may 
invalidate any claims. We recommend that 
after you check the product on delivery that it is 
stored in its packaging to prevent damage prior 
to installation, we cannot accept responsibility 
for items damaged after delivery.

Terms & Conditions

This product is guaranteed for 5 years. As we are not the manufacturers of this 
product we will take all reasonable endeavours to make over to you the benefit of any 
warranty or guarantee given by the manufacturer.
The guarantees in all cases are subject to the products being installed in accordance 
with British and or European standards as well as these fitting instructions. The 
guarantees in all cases are restricted to the free of charge replacement or repair 
of the failed product only. Our liability will under no circumstances extend beyond 
the repair or replacement of the product supplied by us. Claims for either labour in 
replacement or damage to property are not admissible. Any goods that are returned, 
in the event of a problem, will belong to us.

Guarantees & Liabilities

Refer to diagrams overleaf when installing

 

 1. Accurately mark bracket holes on the wall using a tape 

measure and spirit level. The bracket centres are positioned 

153mm down from the top collector, and 103mm from either 

side. 

(Height of the radiator from floor : minimum 100mm)  

 

2. Using suitable drill bits and plugs, insert suitable wall plugs. To 

hang the top two brackets, secure the backplate ‘A’ with screws 

‘B’ (or other suitable screws) going through into the wall plugs. 

 

3. Insert the bracktets ‘C’ down into the back plate ‘A’ and secure 

with the provided screw ‘D’. Then fit the closing cap ‘E’ on top.

4. Hang the radiator on the 

second space

5. With the brackets in the correct position, take 

down the radiator and fit the bottom two brackets by 
repeating steps 1 to 4. 

 

3. Installing radiator

Please Note: In accordance with Part L1 2006 of the 

Building Regulations and BS7593:1992 code of practice for 

the treatment of hot water and central heating systems, 

we strongly recommend flushing the heating system post 

installation of new radiators and then adding the correct 

quantity and type of inhibitor for use with your radiator and 

system to prevent corrosion. Damage caused to systems 

not protected by a suitable inhibitor will not be covered by 

manufacturer’s guarantee.

5. Commission Radiator

E

D

C

A

PLEASE NOTE:

 To reduce the possibility of noise caused by rapid heating and cooling 

of aluminium radiators; adequate capacity for expansion must be provided within 

the overall heating system. Systems using micro bore pipework must have adequate 

pressure and flow rates for the number and style of radiators on the system.

The diverter is marked with a 

yellow cap and is fitted on the 

radiator. The diverter can be 

removed and swapped to the 

other side if required. 

However, we will not be 

liable for any damages to the 

radiator or paint finish as a 

result of moving the diverter.

Diverter

Blanking Plug

4. Identifying the diverter

To Move the Diverter:

 The diverter is situated behind the 

blanking plug on the rear of the bottom collector. (on side marked 
with yellow plug) Remove both the blanking plugs. Lift out the 
cylindrical diverter and place it directly into the opposite collector 
sleeve. Replace blanking plugs. (Please see diagram above).

ALUMINIUM_DESIGNER

Reviews: