Code 93 = 0x41
activation
40 disabled
symbology identifier
C0 “ B6 “
length L1
50 1
length L2
51 0
length L3
52 0
length mode
53 L1 as minimum length
Code 128 / EAN 128 = 0x43
Code 128 activation
40 enabled
Code EAN 128
42 enabled
EAN 128 identifier
58 enabled
GTIN compliant
60 disabled
FNC1 conversion
59 <GS> (1Dh)
ISBT 128
41 disabled
ISBT concatenation transmission
5A disabled
concatenate any pair of ISBT codes
5B disabled
reading range
47 extended
Code 128 symbology identifier
C0 “ B3 “
EAN 128 symbology identifier
C1 “ C9 “
reading tolerance
4F high
check digit verification (French CIP)
4C disabled
length L1
50 0 (any length)
length L2
51 0
length L3
52 0
length mode
53 L1 as minimum length
Interleaved 2 of 5 = 0x44
activation
40 disabled
reading range
47 extended
symbology identifier
C0 “ B2 “
check digit verification
4C disabled
check digit transmission
54 disabled
length L1
50 6
length L2
51 0
length L3
52 0
length mode
53 L1 as minimum length
Matrix 2 of 5 = 0x45
activation
40 disabled
symbology identifier
C0 “ B4 “
length L1
50 6
length L2
51 0