Page 1: ...ower supply cord or convenience receptacle adapter 9 Do not install the track with electric power connected Similarly disconnect electricity when installing or removing fixtures or components or changing the configuration of the track 10 Do not attempt to energize anything other than Lighting Track Fixtures on the track To reduce the risk of fire and electrical shock do not attempt to connect powe...
Page 2: ... 20 A cct Max 20 A Max 20 A L1 L2 N2 N1 L1 L2 N2 N Ground Line2 Line1 Neutral2 Neutral1 polarity ridge HTEK 61 rotating NSPM1 8 27 HTEK 68 with nipple HTEK 68 Switchable between circuits on off Includes rotation lock Max 20lbs 1200W rotation lock screw The fixture adapter is inserted with the polarity groove towards to the polarity ridge on the track Push the adapter into the track till it snaps i...
Page 3: ...one end of track Pass wires through hole on feed and mount track to ceiling using toggle bolts or screws STEP 4 ALWAYS CONNECT GROUND WIRE TO GREEN GROUND TERMINAL Connect live conductors to the appropriate terminal marked L1 or L2 Connect neutral conductors to the appropriate terminal marked N1 or N2 STEP 5 Replace feed connector cover plate INSTALLATION OF HTEK TRACK TO AN OUTLET BOX Outlet Box ...
Page 4: ...g b Maximum 8 ft spacing for stems maximum 24 in long c Each intercept to be directly supported by Pendan Stem or one Pendant Stem shall be provided adjacent each side of intercept maximum 10 in spacing from end of track XX Stem length in inches 1 2 3 4 5 6 7 8 SKB 12 SKB 10 4 Pendant Suspension A Pendant wiring B Mechanical pendant support detail detail Outlet box Thread 3 8 inch 18 IP Thread 3 8...
Page 5: ...dic XTSV 12 bending tool FIELD CUTTING OF TRACK TO LENGTH FIELD DRILLING OF MOUNTING HOLES 1 2 3 4 5 Bending tool XTSV 12 see NOTE If track is field cut it may become necessary to drill new mounting holes If so use one of the off cut pieces with existing mounting hole as a template for new hole to be drilled The drill bit should be no larger than inch in diameter The hole should be centered in the...
Page 6: ... connector TEK 24 Adjustable corner Bent TEK 34 L connector TEK 39 T connector TEK 40 T connector L connector Bent TEK 39 T connector NOTE Dark line directs polarity ridge on track TEK 38 X connector TEK 34 Bent TEK 40 T connector TEK 14 Middle feed INSTALLING CONNECTORS 1 Select the correct connector to fit the end of the track 2 Align the guide lug of the connector with the groove on the track 3...
Page 7: ......
Page 8: ...olvents or cleaning solutions as they may impair the strength of the product Also when changing the location of a fixture adapter DO NOT slide the adapter down the track as it will damage the connectors and cause faulty lighting Fixture must be taken out of track and placed to its desired location Nordic Aluminium Inc 4300C Bankers Circle Doraville GA 30360 Ph 770 326 3331 Fax 770 326 3353 Nordic ...