Nordelettronica NE266S1 Instruction Manual Download Page 4

CONTROL PANEL NE266

GB

GB

4

CONTROLS:

 

 

Push button with warning light for turning 

 

Push button with warning light for turning

 

INTERNAL LIGHTS on or off (*) 

 

 

PUMP on or off(*)

 

Push button with warning light for turning  

 

Push button with warning light for turning

 

INTERNAL LIGHTS on or off (*) 

 

 

AUX on or off (*) 

 

(*) Yellow light colour active load, green light colour deactive load 

 

SCREENS:

 

The warning light goes on when the 230V mains is connected

 

The warning light goes on when 

the vehicle engine is running and the parallel batteries is active   or in the presence of 

the 230V mains when the two batteries are in parallel verifing before the battery service voltage

 

Press the push button to see internal temperature on the display (    ), press the push button twice to view external 
temperature (     ). If you get the message “         “, the temperature sensor is not present.
If the temperature probe is faulty the wording “     “ will appear

The screen remains active for approx. 30 seconds.

 

Pressing this Key for viewing the level percentage % (0,25,50,75,100) of the its reservoir identified with the symbols S1.
If S1 is empty, the display flashes.

If the tank is wrongly connected, the display will show “        “.

The screen remains active for approx. 30 seconds.

 

Repeatedly pressing this Key for viewing the level percentage % (0,100) of the its reservoir identified with the symbols 
R1, R2.
If R1 or R2 are full, the display flashes.

If the tank is wrongly connected, the display will show “        “.

The screen remains active for approx. 30 seconds.

 

Press the push button once to see the voltage on the service battery (B2), Press the push button 
again to see displays the % the remaining battery
The screen remains active for approx. 30 seconds.

 

Press the push button once to see the voltage on the 

, Press the push button 

starter battery (B1)

again to see displays the % the remaining battery
The screen remains active for approx. 30 seconds.

 

ALARMS:

 

Batteries:  Car battery (B1) less than 11,8V or Service battery (B2) less than 10V.

In this case there is a bleep (if enabled) and the flashing battery button  that have generated the alarm
(for the first 30 seconds you see the value)
Hold for more than 3 seconds (     ) button can be disabled (show “         “) or  enabled (show “      “) the low car 
battery alarm
Hold for more than 3 seconds (     ) button can be disabled (show “         “) or  enabled (show “      “) the low service 
battery alarm

 

Tanks:     Tank S1 empty or Recovery tanks R1, R2 full.

In this case there is a bleep (if enabled) and the flashing symbol the corresponding tank that raised the alarm
(for the first 30 seconds you see the value)
Hold for more than 3 seconds (       ) button can be disabled (show “        “) or  enabled (show “      “) the alarm of the 
drinking water tank.
Hold for more than 3 seconds (       ) button can be disabled (show “        “) or  enabled (show “      “) the alarm of the 
recovery tank.

 

Beep:      Hold for more than 3 seconds (       ) button can be disabled (show “        “) or  enabled (show “      “) the the
               confirmation  beep button pressed, and alarm buzzers

 

This symbol appears when there is an error:
 

.      Serial cable connection is wrong 

 

CONSUMPTION:

To turn on the control panel you must  touch for 1 sec. the right or left side panel where there are the keys. The display will 
show the panel firmware version for one second and then the firmware version for the shunt in use for a further second.
The panel after 30 sec. switches to standby mode by turning off all symbols except the keys      and those of active loads.
keys light up when you touch for 1sec. the right or left side panel.
On stand by (no active controls) the control panel with shunt NE185 consumes a total of approx 40mA. When the key       is 
pressed the control panel turns itself off and total consumption is reduced to just 4mA.

If the service battery voltage drops below 10V, after 1  minute the control panel turns itself off, together with all live parts. 

 

CONNECTIONS:

The back of the panel has a connector for serial connection (JP6), a connector for the optional external temperature probe 
(JP10) and a connector for the optional remote internal temperature probe (JP8).

 

ENABLE CLEANING GLASS:

Hold on the button (    ) more than 3 sec will lock all the push button for 1 minute. 