16
LIBERO LINE FRY TOP INDUCTION
TEMPERATURE DISPLAY
MERGED ZONES MODE
Pressing the button the cooking zones will be merged and will be operable
through the left side hand touch panel only.
HOOD TO HOB
(only with coupled Libero Point appliances) This is an advanced automatic function
that connects the hob to the Libero Po
int’s hood. Both the hob and the hood have an infrared signal commu-
nicator. The fan speed is automatically set based on the mode settings and the temperature of the hottest pan
on the hob. It is also possible to operate the fan from the hob manually pressing one to four times the button.
WIRLESS
to be implemented.
1.7 GLOSSARY AND ABBREVIATIONS
POW
Induction Power Board. Sometimes referred also
as “Hob Control” (HC) or “POB”
HC
Hob Control, sometimes referred also
as “Power Board” (POW).
TESLA
Single-phase, Double generator, 3500W
Induction Power Board.
FOUCAULT
3-phase, Single generator, 5000W
Induction Power Board.
UI
User Interface
HUI
Hob User Interface
ROADRUNNER
User Interface
PD or HPD
Hob Pot Detection. A circuit, normally embedded in a POW, able to detect pot presence over
a coil.
HOB
Induction Hob
cooking appliance
WOK
Induction WOK
cooking appliance
FRY
Induction Fry Top cooking appliance
SZ
Single Zone (cooking appliance)
DZ
Double Zone (cooking appliance)
1PH
Single-phase power supply line
3PH
3-phase power supply line
MACS
Mayor Appliance Communication System. A communication protocol used in Electrolux commercial
appliances.
HCS
Hob Communication System protocol. A MACS-based protocol variant, especially dedicated to Hob
appliances.
DAAS
Data Acquisition protocol. A MACS-based protocol variant, especially dedicated to exchange raw data
between electronic devices/boards.
APD
Disconnection relay. Power relay, belonging to POW circuits that supplies power to the induction
circuits.
SW
Software
HW
Hardware
§
chapter / paragraph
MACHINE
or
“appliance“ or “unit”
Summary of Contents for 406600899
Page 1: ...Service Manual Fry Induction Top IGEC 3P 2ZQT Art 406600899 2021 04 ...
Page 13: ...13 LIBERO LINE FRY TOP INDUCTION DOUBLE ZONE ...
Page 21: ...21 LIBERO LINE FRY TOP INDUCTION In case of need the supply cable can be replaced removed ...
Page 44: ...44 LIBERO LINE FRY TOP INDUCTION ...
Page 45: ...45 LIBERO LINE FRY TOP INDUCTION ...
Page 47: ...47 LIBERO LINE FRY TOP INDUCTION ...
Page 48: ...48 LIBERO LINE FRY TOP INDUCTION ...
Page 50: ...50 LIBERO LINE FRY TOP INDUCTION ...
Page 51: ...51 LIBERO LINE FRY TOP INDUCTION ...
Page 54: ...54 LIBERO LINE FRY TOP INDUCTION ...