11. Module reference: Note group
NORD MODULAR G2 V1.1
Page 116
N
N
N
N
O
O
O
OT
T
T
TE
E
E
E
D
D
D
D
E
E
E
ET
T
T
TE
E
E
EC
C
C
CT
T
T
T
This module can detect a note, either
from the Nord Modular G2 keyboard or
from the
MIDI
INPUT
. A logic high sig-
nal will be transmitted, together with a velocity control signal, when the selected key is detected. The logic
signal will switch to zero, and a release velocity control signal will be sent, when the selected key is re-
leased. The Note Detect module is global and affects all voices assigned in a patch. The behavior is similar
to the MonoKey module described on
. The Note detect module is not affected by the polyph-
ony of the patch. It will detect notes, even if you run out of polyphony.
N
N
N
N
O
O
O
OT
T
T
TE
E
E
E
K
K
K
KN
N
N
NO
O
O
OB
B
B
B
Select the note to be detected. Range: C-1 to G9.
O
O
O
O
U
U
U
UT
T
T
TP
P
P
PU
U
U
UT
T
T
TS
S
S
S
Gate signal:
Logic
.
Velocity (linear Velocity signal):
Unipolar Positive
.
RelVel (linear Release Velocity signal):
Unipolar Positive
.
N
N
N
N
A
A
A
AM
M
M
ME
E
E
E
The Name module hasn’t any “musical”
function in the Patch except for “visual
help and guidance”. It’s very handy if you, for example, want to describe a group of modules in the Patch
window. Just place the Name module together with the modules in the group, right-click on the Name
module and select ‘Rename’ from the pop-up and give it an appropriate name. Then press Enter to apply
the name to the module.
Tip! To distinguish a group of modules in the Patch from other modules, you can also use the Color fea-
ture described on
.
N
N
N
N
O
O
O
OT
T
T
TE
E
E
E
G
G
G
GR
R
R
RO
O
O
OU
U
U
UP
P
P
P
N
N
N
N
O
O
O
OT
T
T
TE
E
E
E
Q
Q
Q
Q
U
U
U
UA
A
A
AN
N
N
NT
T
T
T
This module will quantize the values of a
continuous control signal to produce dis-
crete, semitone steps. The total range of
the incoming signal can be attenuated at
the input.
R
R
R
RA
A
A
AN
N
N
NG
G
G
GE
E
E
E
D
D
D
DIIIIS
S
S
SP
P
P
PL
L
L
LA
A
A
AY
Y
Y
Y
B
B
B
BO
O
O
OX
X
X
X
Displays the note range. Range: 0 to +/-64 semitones. Note that for the display box to show the correct
limits, it is assumed that the input signal uses the full range -64 to +64 semitones.
R
R
R
R
A
A
A
AN
N
N
NG
G
G
GE
E
E
E
K
K
K
KN
N
N
NO
O
O
OB
B
B
B
Set the signal range with the knob.
N
N
N
N
O
O
O
OT
T
T
TE
E
E
ES
S
S
S
D
D
D
DIIIIS
S
S
SP
P
P
PL
L
L
LA
A
A
AY
Y
Y
Y
B
B
B
BO
O
O
OX
X
X
X
Displays the selected quantization grid (interval) in semitones. Range: Off, 1-127.