4 Commissioning
BU 0135 GB-2713
Pre-series version
47
4.2.2.2 DIP switches
Individual functions of the motor starters can be set by means of a quadruple DIP switch. These differ ac-
cording to the equipment version.
DIP
switches
Functionality
Functionality
105E
145E
115E
155E
125E
165E
135E
175E
DIP1
Automatic start
0: Enable with flank
1: Enable with level
+
+
+
+
DIP2
Phase sequence
detection
0: According to phase sequence
Mains connection
1: According to phase sequence
Required direction of rotation
Automatic detection of
phase sequence
+
+
DIP2
Switch off with error in
case of
overtemperature
0: Starter switches off on
overtemperature
1: No switch off on
overtemperature
only warning
+
*
DIP3
Release the brake
0: Brake released on
enable
1: Brake is permanently
released
+
+
DIP4
Switch off with error in
case of
overtemperature
0: Starter switches off on
overtemperature
1: No switch off on
overtemperature
only warning
+
+
*
DIP3, 4
Switch-off ramp
00: Deceleration mode 1
01: Deceleration mode 2
10: Deceleration mode 3
11: Deceleration mode 4
+
+
* For SK 135E and SK 175E devices the function "Switch off with error on overtemperature" can only be ena-
bled via parameter P580.
4 3 2 1
ON
OFF