2 Description of the drive
B 5000 en-2621
21
2.4.5 Motor to frequency inverter assignment
The following assignments of the motors to the suitable frequency inverters apply to nominal
operation. Deviating operating conditions require planning and, if necessary, an adjustment of the
inverter assignment.
Motor data
C
la
ss
ific
at
ion of
fr
eq
ue
nc
y
in
ver
ter
s an
d
m
ot
or
s
Q
ua
nti
ty
M
N
[Nm
]
P
N
[k
W
]
n
N
[rp
m
]
I [
A]
η
J [
kg
m
2
]
m [
kg
]
M
ma
x
[Nm
]
k
T
[Nm
/A]
K
E
[m
V/
rp
m
]
71N1/8 1,6
0,35
2100
0,76 89,1 0,00019
4,9
4,8
2,1
143
-370-340
-550-340
71N2/8 3,2
0,7
2100
1,45 92,5 0,00038
6,0
9,6
2,2
144
-750-340
71N3/8 4,8
1,1
2100
2,14 93,6 0,00057
7,0
14,4
2,2
144
-111-340-
80T1/4
5,0
1,1
2100
2,07 90,5 0,0011
8,0
14,4
2,5
154
-111-123-
-111-323-
-111-340-
80T1/4
HM
3,41 0,75
2100
1,46 90,5 0,0011
7,8
14,4
2,3
154
-111-123-
-111-323-
-111-340-
80T1/4
Δ
4,8
1,5
3000
3,44 90,4 0,0011
8,0
14,4
1,4
89
-151-340-
90N1/8 5,0
1,1
2100
2,1
94,0 0,0009
10,0
15,0
2,38
144
-111-340-
90N2/8 6,8
1,5
2100
3,01 94,0 0,0011
10,8
20,5
2,27
144
-151-340-
90N3/8 10,0
2,2
2100
4,35 94,6 0,00176
13,2
30,0
2,3
142
-221-340-
90T1/4
6,8
1,5
2100
2,82 89,9 0,0019
10,0
21,0
2,4
156
-151-323-
-151-340-
90T1/4
Δ
7,0
2,2
3000
5,09 89,6 0,0019
10,0
21,0
1,4
90
-221-340-
90T3/4 10,0
2,2
2100
4,13 90,5 0,0024
12,0
29,0
2,4
158
-221-323-
-221-340-
90T3/4
HM
5,0
1,1
2100
2,08 92,7 0,0024
11,6
28,3
2,4
156
-151-323-
-151-340-
90T3/4
Δ
9,5
3,0
3000
6,84 92,3 0,0024
12,0
29,0
1,4
91
-301-340-
100T2/4 13,6
3,0
2100
5,4
91,4 0,00416
18,0
42,0
2,6
161
-301-323-
-301-340-
100T2/4
Δ
12,7
4,0
3000
8,9
92,1 0,0046
18,0
42,0
1,5
93
.401-340-
100T5/4 18,2
4,0
2100
7,1
92,1 0,0060
21,0
57,0
2,6
165
-401-323-
-401-340-
100T5/4
HM
10,0
2,2
2100
4,16 91,0 0,0060
20,2
53,5
2,4
165
-301-323-
-301-340-
100T5/4
Δ
17,5
5,5
3000
11,9 92,2 0,0060
21,0
57,0
1,5
95
-551-340-
Table 7: Motor to frequency inverter assignment