Norcon Communications TTU-1X Series User Manual Download Page 1

 

 

 

 

 

Norcon TTU® -1X Series 

Installation & Operating 

Instructions 

***** 

510    Burnside    Ave. 

Inwood. NY 11096 

Tel.    516 239 0300 
Fax.   516 239 8915 

www.norcon.org

                                                

                                    

 

 

 

 

Introduction      ……………………………………..1 

 

Features …………………………………………….1 

 

How It Works …………………………………….…2 

 

How To Install …………………………………….. 3-4 

 

How To Use The Talk-Thru Communicator ……. 5 

 

Operation Hints  ………………………………….   6 

 

Specifications ……………………………………… 7 

 

Accessories and Options ….……………………… 8 

 

TTU® -1X  Series    ……………….……  ……….   9 

 

Norcon TTU®-7X Series   ……………...………....11 

 

Norcon TTU®-3X Series.…  ….…………....……. 12 

 

Troubleshooting ………………….…….…………..13 

 

Warranty ……………………………….…………...14

 

 

 

 
 
 

TTU® -1X Series 2-Way Talk-Thru Electronic       

Communication System.

 

       A voice communications system for High-Security and Isolation 
Booth Situations.  In today’s security conscious environment, 
isolation booths are often the ideal recourse to protect your 
employees. But does it facilitate and help maintain your very 
important public image? Not if clerks and customers have to yell and 
repeat themselves to be heard or understood. 

Norcon’s Patented TTU® -1X Talk-Thru Communicator

  is a 2-

way, hands-free audio system that provides high-quality personal 
communication between people separated by security or isolation 
barriers. It is the most widely used system of its type in the U.S., and 
the world.

  

 
FEATURES 

 

Clear 2-way hands-free voice communication.  

 

Quality electronic design and engineering.  

 

Avoid raising your voice, repetition & misunderstanding. 

 

XLR removable mic for your convenience. 

 

Simple, one-person installation.  

 

Rugged, tamper-resistant materials. Anodized aluminum 

 

Self-powered with fast rechargeable battery option. 

 

Bullet-resistant option (UL level 3). 

 

Units available for ADA applications. 

 

Headset jack equipped on all models. Headset can be ordered 
separately.  

 

Export models available 

 
 

1

 

 

 

 

HOW IT WORKS … 

      

The Norcon TTU® system permits hands-free, 2-way 

communication between the booth attendant and the customer. 
Unique circuitry facilitates ongoing, clear, 2-way conversation at all 
times – as if the two parties were together in the same room. The 
TTU®-1X Talk-Thru Communicator now incorporates circuitry to 
automatically attenuate the outside channel. If the gooseneck 
microphone is not used for a period of 30 seconds, the outside 
channel volume will be reduced approximately 70%. Normal operation 
is restored as soon as the attendant speaks into the gooseneck 
microphone. The automatic volume attenuation circuit prevents 
outside noise from bothering the attendant. 
        The TTU® -1X provides clear communication even in 
environments with high ambient noise by shaping the sound for 
maximum intelligibility. Its compression circuitry decreases loud, 
annoying sounds.        

  
 

HOW TO INSTALL …

     

Installation of the TTU® -1X is a very simple, one-person operation. 
All that’s needed is a 3” to 4” diameter cutout in the barrier. Four 
fasteners and two rubber gaskets for mounting are supplied. The front 
face and housing are easily mounted on opposite sides of the barrier 
using the fasteners. The rubber gaskets prevent slippage and protects 
the barrier surface. The electronic section is then inserted into the 
housing and fastened in place. 

 
 
 

2

 

 

 

 
 

 

 

 

 
 

 

 
 
 
 
Installation Instructions: 

  Remove the four (4) 6-32 assembly screws. 
  Separate the housing and electronics assembly. Unplug  electronic 

assembly from the faceplate and housing. 

 

Set the electronic assembly aside, carefully. 

  Remove the four (4) 8-32 mounting nuts from the mounting rods. 

Separate the faceplate and housing. Discard the shipping spacers 
located between the faceplate and housing if there are any. Hold the 
faceplate over the partition opening. Carefully center the faceplate and 
align the lettering horizontally. Masking tape can be used to temporarily 
hold the faceplate to the outside of the partition. 

  On the inside of the partition mount the housing over the four (4) 8-32 

mounting rods. Be certain to position the housing so that the threaded 
hole is positioned properly. If using tubing, orient the hole in the direction 
which the tubing is to exit (left, right, top, and bottom). If tubing is  not 
being used, place the plugged hole at the bottom. 

Recommended cables for wiring : 

For power connections use 

West Penn wire #221

. This is a stranded 

single pair 22  awg, Plenecon -II jacket Rohs cable. Keep Mic/spk and 
power cable bundles away from other power cable. 
For power connection, route the one pair cable (with the connector on 
one end). From the inside unit to the location of the PS-1 power supply. 
Connect the conductors to the power supply (RED to +ve,  
BLACK to -ve).  Plug the connector to its mate from the printed circuit 
board. Connect 4 – pin polarized connectors and reassemble units 

 
 
 
 
 

3

 

 

 
 
 

 

Place the housing so that the threaded hole can be positioned    
properly. If using tubing, orient the hole in the direction in which the 
tubing is to exit as shown in the drawing. 

 

 
 
 

HOW TO USE THE TALK-THRU COMMUNICATOR... 

1.  With power switch off, turn Talk and Listen controls 
completely counter clockwise. 

2.  Turn on the unit by switching the Power ON/OFF switch to its 

upper position. At this position, the unit is at the auto mute 
mode. 

3. 

 Adjust the TALK volume control until the attendant is clearly heard 

by the person outside the window when the attendant is speaking 2" 
to 4" from the gooseneck microphone at a normal speaking level. The 
green LED should go on when the attendant starts talking and go off 
when the attendant stops talking. 

If the green LED stays lit 

constantly, it indicates either the TALK volume setting or the 
ambient noise is too high. 

4. Adjust the LISTEN control until the person outside the window is 

clearly heard when speaking at a normal level. 

 

4    

 

              
     
                   

 

 

OPERATION HINTS

  1.  Increasing the talk volume control allows the attendant to 

speak further away from the microphone as well as increasing 
the talk channel volume. The optimum distance from the 
microphone should be maintained at approximately 2”-4” or 
conversations not directed to customers may be heard outside 
the booth. Watch the green LED above the TALK volume 
control, it should be ON only when talking into the gooseneck 
microphone and off when not talking to the microphone. 

2.     Installing a headset into the Headset jack will allow 

communications from the headset and disconnect the speaker 
and the gooseneck microphone. 

3.     The unit will decrease the incoming volume level by 

approximately 70% some 30 seconds after the attendant stops 
speaking into the microphone. The purpose of this feature is to 
decrease the amount of extraneous noise entering the booth. 
Normal volume level is restored when the attendant speaks 
into the microphone. The muting function can be defeated by 
switching the POWER SWITCH to the NO MUTE position. 

 

 

SPECIFICATIONS: 

MECHANICAL: 

 

Outside faceplate: Aluminum, anodized finish, tamper-resistant. 

 

Control housing (inside): Machined aluminum, anodized finish, 
tamper-resistant. 

 

Size: Outside faceplate 5” Dia. x ½” D. Inside control housing: 
  

  5” Dia. x 2-1/2” D (TTU®-1 AX) (TTU®-1 AX) 

         5” Dia. x 3-1/2” D (TTU®-1 D X) (TTU®-1 ABX) 

 

Weight: ~ 5 LB. 

 

Mounting: 

Partition hole 3 to 4” Dia. (3-1/2” recommended) 

Specify barrier thickness when ordering. Norcon will adjust 
the length of the mounting rods to meet your need. 

Panel Controls: LISTEN volume, TALK volume, POWER On/Off, 
AUTO MUTE On/Off. 

ELECTRONIC: 

 

Audio frequency response: Selectively shaped for maximum voice 
intelligibility. 

 

Audio power: 2 watts per amplifier. 

 

Distortion: Less than 2%. 

 

Listen mode: 20dB compression. 

 

Microphone: Electret. 

 

Power Supply Adapter: Input 90-240V AC, 60 Hz. Output 15V 
DC, 1A. UL, (Canada and US) CE, level VI. 

Specifications are subject to change without notice. 

                                                                                                 

                                                        6

                                        

TTU-1A XLR P.1.

 

Be certain to position the housing so that the threaded hole can 
be positioned properly. If using tubing, orient the hole in the 
direction which tubing is to exit. 

  

   

  

Summary of Contents for TTU-1X Series

Page 1: ...Norcon TTU 1X Series Installation Operating Instructions 510 Burnside Ave Inwood NY 11096 Tel 516 239 0300 Fax 516 239 8915 www norcon org...

Page 2: ...ow It Works 2 How To Install 3 4 How To Use The Talk Thru Communicator 5 Operation Hints 6 Specifications 7 Accessories and Options 8 TTU 1X Series 9 Norcon TTU 7X Series 11 Norcon TTU 3X Series 12 Tr...

Page 3: ...ree audio system that provides high quality personal communication between people separated by security or isolation barriers It is the most widely used system of its type in the U S and the world FEA...

Page 4: ...seneck microphone The automatic volume attenuation circuit prevents outside noise from bothering the attendant The TTU 1X provides clear communication even in environments with high ambient noise by s...

Page 5: ...unt the housing over the four 4 8 32 mounting rods Be certain to position the housing so that the threaded hole is positioned properly If using tubing orient the hole in the direction which the tubing...

Page 6: ...control until the attendant is clearly heard by the person outside the window when the attendant is speaking 2 to 4 from the gooseneck microphone at a normal speaking level The green LED should go on...

Page 7: ...gooseneck microphone and off when not talking to the microphone 2 Installing a headset into the Headset jack will allow communications from the headset and disconnect the speaker and the gooseneck mic...

Page 8: ...ommended Specify barrier thickness when ordering Norcon will adjust the length of the mounting rods to meet your need Panel Controls LISTEN volume TALK volume POWER On Off AUTO MUTE On Off ELECTRONIC...

Page 9: ...he position of around 11 to 12o clock Conversation cutting off and breaking up Is the TALK volume setting too high Turn down TALK volume to a proper level Make sure the green LED is off when not talki...

Page 10: ...CX same as TTU 1AX without gooseneck microphon for headset use only TTU 1DX Battery operated unit Complete with rechargeable batteries and charger Housing 5 Dia x 3 depth TTU 1DBX same as TTU 1DX but...

Page 11: ...s a pair of 6 or 12 prism shaped units for mounting on a counter top on both sides of a barrier They allow hands free communication through barriers typically found in banks cashier s booths informati...

Page 12: ...hen it s impractical to mount the inside control section of the TTU 3X in a window with secure gate or shade the TTU 7X is your choice The TTU 7X incorporates the same high quality electronics as the...

Page 13: ...nt noise environment and attenuate the noise around the desired speech signals As a result continuous and repetitive noise is removed a clear conversation will be even with a passing truck in the back...

Page 14: ...feet from base unit Duo Set Headset Adjustable for over the head stability or over the ear convenience with new conformable ear loop Extended Use Ten hours continuous talk time on rechargeable batter...

Page 15: ...ty engineering and innovative design Walk around freely while talking to the customer Self powered unit with rapid rechargeable battery Microphone Grill Windscreen Sponge Specification Material Foam C...

Page 16: ...ightning water damage flooding fire explosion earthquakes tornadoes acts of aggressions war or similar phenomenon and 3 The product has been properly installed according to the appropriate Norcon Inst...

Reviews: