4
Trouble Shooting - Procedure B
Figure 2 - Measuring Compressor Resistance
Turn the refrigerator to OFF.
Remove the black wire to the compressor. Measure
the resistance of the compressor bewteen Point A and
Point B.
A
B
Note: Perform procedure at room temperature.
Change
Cooling Unit
Measure
compressor
resistance
0
Internal Compressor
Failure
Normal
See Procedure C
3
+/-.5
ART01192
Compressor Resistance